CTRON-POWER-SUPPLY-MIB :: psPowerMinVoltage

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCTRON-POWER-SUPPLY-MIBpsPowerMinVoltage

psPowerMinVoltage

Module: CTRON-POWER-SUPPLY-MIB

OID (symbolic): CTRON-POWER-SUPPLY-MIB::psPowerMinVoltage

OID (numeric): 1.3.6.1.4.1.52.4.1.1.7.3.2.1.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The minimum voltage for this power line. If the voltage reading for this power line is greater than this value then the power line is considered to be in an over volatge condition. The value of this object is voltage * 100.

What is psPowerMinVoltage?

This is the lower voltage threshold for this power supply line; a reading below it is treated as an undervoltage condition. Admins reference it when psPowerStatus reports underVoltage.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.7.3.2.1.10
snmpwalk -v2c -c public <target> CTRON-POWER-SUPPLY-MIB::psPowerMinVoltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.7.3.2.1.10.1
snmpget -v2c -c public <target> CTRON-POWER-SUPPLY-MIB::psPowerMinVoltage.1

Start monitoring Cabletron modular switch/router (power supply health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-POWER-SUPPLY-MIB::psPowerMinVoltage OID value, configure state conditions and alerts, and monitor any Cabletron modular switch/router (power supply health) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCTRON-AP3000-MIB
1.3.6.1.4.1.52.4.1ctronCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.1ctPhysicalCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.1.7ctpsCTRON-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.52.4.1.1.7.3psPowerCTRON-POWER-SUPPLY-MIB
1.3.6.1.4.1.52.4.1.1.7.3.2psPowerSlotTableCTRON-POWER-SUPPLY-MIB
1.3.6.1.4.1.52.4.1.1.7.3.2.1psPowerSlotEntryCTRON-POWER-SUPPLY-MIB
1.3.6.1.4.1.52.4.1.1.7.3.2.1.10psPowerMinVoltageCTRON-POWER-SUPPLY-MIB