chPowerMainVoltageStatus

Module: CTRON-POWER-SUPPLY-MIB

OID (symbolic): CTRON-POWER-SUPPLY-MIB::chPowerMainVoltageStatus

OID (numeric): 1.3.6.1.4.1.52.4.1.1.7.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This object reflects the state of the main voltage rail within the chassis. The power on this rail may be delivered by AC supplies, DC supplies or battery supplies.

What is chPowerMainVoltageStatus?

This shows whether the chassis's main power rail is at a normal voltage or in an overCurrent, overVoltage, or underVoltage fault condition. Admins poll it to catch a failing power supply or busbar problem before it takes down installed modules. A value other than powerOK(1) warrants checking chPowerMainVoltage and the physical supplies feeding that rail.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.7.1.2
snmpwalk -v2c -c public <target> CTRON-POWER-SUPPLY-MIB::chPowerMainVoltageStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.7.1.2.1
snmpget -v2c -c public <target> CTRON-POWER-SUPPLY-MIB::chPowerMainVoltageStatus.1

Start monitoring Cabletron modular switch/router (power supply health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-POWER-SUPPLY-MIB::chPowerMainVoltageStatus OID value, configure state conditions and alerts, and monitor any Cabletron modular switch/router (power supply health) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCTRON-AP3000-MIB
1.3.6.1.4.1.52.4.1ctronCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.1ctPhysicalCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.1.7ctpsCTRON-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.52.4.1.1.7.1chPowerCTRON-POWER-SUPPLY-MIB
1.3.6.1.4.1.52.4.1.1.7.1.2chPowerMainVoltageStatusCTRON-POWER-SUPPLY-MIB