Access: read-only
Description: The voltage of the chassis's main voltage rail. This rail carries power to all the modules in the chassis. It has an allowable range of 40 volts to 60 volts DC. The value of this object is the actual voltage * 10.
What is chPowerMainVoltage?
This is the measured voltage on the chassis's main power rail, which should sit between 40 and 60 volts DC; the reported integer is the actual voltage multiplied by 10. An admin divides the raw value by 10 to get real volts and compares it against that allowed range when diagnosing a chPowerMainVoltageStatus fault, e.g. a reading of 480 means 48.0 volts.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.7.1.3 snmpwalk -v2c -c public <target> CTRON-POWER-SUPPLY-MIB::chPowerMainVoltage
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.7.1.3.1 snmpget -v2c -c public <target> CTRON-POWER-SUPPLY-MIB::chPowerMainVoltage.1
Start monitoring Cabletron modular switch/router (power supply health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-POWER-SUPPLY-MIB::chPowerMainVoltage OID value, configure state conditions and alerts, and monitor any Cabletron modular switch/router (power supply health) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CTRON-AP3000-MIB |
| 1.3.6.1.4.1.52.4.1 | ctron | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.1 | ctPhysical | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.1.7 | ctps | CTRON-MIB-NAMES |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.1.1.7.1 | chPower | CTRON-POWER-SUPPLY-MIB |
| 1.3.6.1.4.1.52.4.1.1.7.1.3 | chPowerMainVoltage | CTRON-POWER-SUPPLY-MIB |