CTRON-POWER-SUPPLY-MIB :: chPowerLineMaxLoad

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCTRON-POWER-SUPPLY-MIBchPowerLineMaxLoad

chPowerLineMaxLoad

Module: CTRON-POWER-SUPPLY-MIB

OID (symbolic): CTRON-POWER-SUPPLY-MIB::chPowerLineMaxLoad

OID (numeric): 1.3.6.1.4.1.52.4.1.1.7.1.8.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The maximum load that could be presented by the chassis to the chassis's power supplies on this power line. The value of this object is the actual watts.

What is chPowerLineMaxLoad?

This is the maximum power, in watts, this particular backplane power line is rated to carry before being considered overloaded. Admins use it with chPowerLineTotalLoad to detect an overloaded bus even while the chassis overall still has power headroom.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.7.1.8.1.6
snmpwalk -v2c -c public <target> CTRON-POWER-SUPPLY-MIB::chPowerLineMaxLoad

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.7.1.8.1.6.1
snmpget -v2c -c public <target> CTRON-POWER-SUPPLY-MIB::chPowerLineMaxLoad.1

Start monitoring Cabletron modular switch/router (power supply health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-POWER-SUPPLY-MIB::chPowerLineMaxLoad OID value, configure state conditions and alerts, and monitor any Cabletron modular switch/router (power supply health) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCTRON-AP3000-MIB
1.3.6.1.4.1.52.4.1ctronCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.1ctPhysicalCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.1.7ctpsCTRON-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.52.4.1.1.7.1chPowerCTRON-POWER-SUPPLY-MIB
1.3.6.1.4.1.52.4.1.1.7.1.8chPowerTableCTRON-POWER-SUPPLY-MIB
1.3.6.1.4.1.52.4.1.1.7.1.8.1chPowerEntryCTRON-POWER-SUPPLY-MIB
1.3.6.1.4.1.52.4.1.1.7.1.8.1.6chPowerLineMaxLoadCTRON-POWER-SUPPLY-MIB