CTRON-POWER-SUPPLY-MIB :: boardPowerPriority

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCTRON-POWER-SUPPLY-MIBboardPowerPriority

boardPowerPriority

Module: CTRON-POWER-SUPPLY-MIB

OID (symbolic): CTRON-POWER-SUPPLY-MIB::boardPowerPriority

OID (numeric): 1.3.6.1.4.1.52.4.1.1.7.2.1.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The module's power-up and power down priority. This is a value of 1 to 14 and is used to decide which modules are allowed to power on in the event that power demand of the chassis is greater than the total power supply. The default value is 14, highest priority. When two modules have equal priority then the module in the lowest slot wins.

What is boardPowerPriority?

This sets a module's power-up/power-down priority from 1 to 14, used to decide which cards stay powered when total power demand exceeds supply; 14 (the default) is highest priority, and ties go to the card in the lowest slot number. An admin raises this value on a critical uplink module so it's the last to be shed during a power shortfall.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.7.2.1.1.7
snmpwalk -v2c -c public <target> CTRON-POWER-SUPPLY-MIB::boardPowerPriority

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.7.2.1.1.7.1
snmpget -v2c -c public <target> CTRON-POWER-SUPPLY-MIB::boardPowerPriority.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.1.1.7.2.1.1.7.1 i <value>

Start monitoring Cabletron modular switch/router (power supply health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-POWER-SUPPLY-MIB::boardPowerPriority OID value, configure state conditions and alerts, and monitor any Cabletron modular switch/router (power supply health) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCTRON-AP3000-MIB
1.3.6.1.4.1.52.4.1ctronCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.1ctPhysicalCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.1.7ctpsCTRON-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.52.4.1.1.7.2boardPowerCTRON-POWER-SUPPLY-MIB
1.3.6.1.4.1.52.4.1.1.7.2.1boardPowerSlotStatusTableCTRON-POWER-SUPPLY-MIB
1.3.6.1.4.1.52.4.1.1.7.2.1.1boardPowerSlotStatusEntryCTRON-POWER-SUPPLY-MIB
1.3.6.1.4.1.52.4.1.1.7.2.1.1.7boardPowerPriorityCTRON-POWER-SUPPLY-MIB