All MIBs › CTRON-ENVIRONMENT-MIB › boardEnvTempMaxFanRelWarm
boardEnvTempMaxFanRelWarm
Module: CTRON-ENVIRONMENT-MIB
OID (symbolic): CTRON-ENVIRONMENT-MIB::boardEnvTempMaxFanRelWarm
OID (numeric): 1.3.6.1.4.1.52.4.1.1.8.2.1.1.13
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The temperature value above ambient at which the board temperature is deemed to be warm relative to ambient, if it is below the relative hot value of boardEnvTempMaxFanRelHot, with all fans in the chassis running at there maximum speed.
What is boardEnvTempMaxFanRelWarm?
This is the configured relative-warm threshold used when fans are already running at maximum speed, giving an earlier warning within that worst-case cooling scenario, and set below boardEnvTempMaxFanRelHot. It signals a developing thermal issue even though full cooling is already engaged and there's no more cooling headroom to apply. For example, crossing this threshold while fans are already maxed suggests planning for possible shutdown soon if the temperature keeps climbing toward the hot threshold.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.8.2.1.1.13 snmpwalk -v2c -c public <target> CTRON-ENVIRONMENT-MIB::boardEnvTempMaxFanRelWarm
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.8.2.1.1.13.1 snmpget -v2c -c public <target> CTRON-ENVIRONMENT-MIB::boardEnvTempMaxFanRelWarm.1
Start monitoring Cabletron/Enterasys modular chassis switch/router/hub (environmental sensors) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-ENVIRONMENT-MIB::boardEnvTempMaxFanRelWarm OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys modular chassis switch/router/hub (environmental sensors) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.1 | ctron | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.1 | ctPhysical | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.1.8 | ctenv | CTRON-MIB-NAMES |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.1.1.8.2 | boardEnv | CTRON-ENVIRONMENT-MIB |
| 1.3.6.1.4.1.52.4.1.1.8.2.1 | boardEnvSlotTable | CTRON-ENVIRONMENT-MIB |
| 1.3.6.1.4.1.52.4.1.1.8.2.1.1 | boardEnvSlotEntry | CTRON-ENVIRONMENT-MIB |
| 1.3.6.1.4.1.52.4.1.1.8.2.1.1.13 | boardEnvTempMaxFanRelWarm | CTRON-ENVIRONMENT-MIB |