All MIBs › CT-FASTPATH-DHCPSERVER-MIB › ctAgentDhcpServerPoolOptionHexData
ctAgentDhcpServerPoolOptionHexData
Module: CT-FASTPATH-DHCPSERVER-MIB
OID (symbolic): CT-FASTPATH-DHCPSERVER-MIB::ctAgentDhcpServerPoolOptionHexData
OID (numeric): 1.3.6.1.4.1.52.4.2.32.1.2.7.1.5
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-write
Description: This specifies semi-colon separated hexadecimal data. Two hexadecimal digits in hexadecimal character string represents one byte . Hexadecimal strings can be entered in the following formats : 1) continuous hexadecimal digits like -- 0123456789abcdef 2) hexadecimal digits separated by space ' ' -- 01 23 45 67 de 0f 3) Two hexadecimal digits separated by delimeter ':' -- 01:02:a0 de:0f 78:5e 4) Four hexadecimal digits separated by delimeter '.' -- 01ab.c0de.7865 If a Hex optiondata is entered again, it gets concatenated with the previous Hex data.
What is ctAgentDhcpServerPoolOptionHexData?
This read-write DisplayString, up to 1324 characters, specifies semicolon-separated hexadecimal data for a DHCP option, accepting several input formats including continuous digits, space-separated, or colon-separated hex bytes. An administrator uses this to configure binary DHCP option values that aren't naturally expressed as ASCII text or IP addresses. For example, an admin setting a raw vendor-specific binary option would enter its bytes as hex pairs via ctAgentDhcpServerPoolOptionHexData.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.32.1.2.7.1.5 snmpwalk -v2c -c public <target> CT-FASTPATH-DHCPSERVER-MIB::ctAgentDhcpServerPoolOptionHexData
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.32.1.2.7.1.5.1 snmpget -v2c -c public <target> CT-FASTPATH-DHCPSERVER-MIB::ctAgentDhcpServerPoolOptionHexData.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.32.1.2.7.1.5.1 s <value>
Start monitoring Enterasys/Cabletron FastPath switch (DHCP server) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CT-FASTPATH-DHCPSERVER-MIB::ctAgentDhcpServerPoolOptionHexData OID value, configure state conditions and alerts, and monitor any Enterasys/Cabletron FastPath switch (DHCP server) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CTRON-AP3000-MIB |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.2.32 | ctDhcpServerExpMib | CTRON-MIB-NAMES |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.32.1 | ctFastPathDHCPServerMIB | CT-FASTPATH-DHCPSERVER-MIB |
| 1.3.6.1.4.1.52.4.2.32.1.2 | ctAgentDhcpServerPoolConfigGroup | CT-FASTPATH-DHCPSERVER-MIB |
| 1.3.6.1.4.1.52.4.2.32.1.2.7 | ctAgentDhcpServerPoolOptionTable | CT-FASTPATH-DHCPSERVER-MIB |
| 1.3.6.1.4.1.52.4.2.32.1.2.7.1 | ctAgentDhcpServerPoolOptionEntry | CT-FASTPATH-DHCPSERVER-MIB |
| 1.3.6.1.4.1.52.4.2.32.1.2.7.1.5 | ctAgentDhcpServerPoolOptionHexData | CT-FASTPATH-DHCPSERVER-MIB |