CORIANT-GROOVE-MIB :: inletTemperatureMax

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCORIANT-GROOVE-MIBinletTemperatureMax

inletTemperatureMax

Module: CORIANT-GROOVE-MIB

OID (symbolic): CORIANT-GROOVE-MIB::inletTemperatureMax

OID (numeric): 1.3.6.1.4.1.42229.1.2.13.40.1.1.4

Node type: OBJECT-TYPE

Type: CoriantTypesTemperaturePrecision3

Access: read-only

Description: the maximum value of statistics counter

What is inletTemperatureMax?

This read-only value is the highest inlet air temperature recorded during the current statistics interval. It is the leading warning sign of a cooling failure, since it directly reflects the hottest air entering the shelf before internal components warm further. For example, a sudden jump in inletTemperatureMax during a data-center HVAC outage would trigger an alarm well before module temperatures themselves become critical.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.42229.1.2.13.40.1.1.4
snmpwalk -v2c -c public <target> CORIANT-GROOVE-MIB::inletTemperatureMax

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.42229.1.2.13.40.1.1.4.1
snmpget -v2c -c public <target> CORIANT-GROOVE-MIB::inletTemperatureMax.1

Start monitoring Coriant Groove optical transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CORIANT-GROOVE-MIB::inletTemperatureMax OID value, configure state conditions and alerts, and monitor any Coriant Groove optical transport platform from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.42229coriantCORIANT-GROOVE-MIB
1.3.6.1.4.1.42229.1productsCORIANT-GROOVE-MIB
1.3.6.1.4.1.42229.1.2grooveCORIANT-GROOVE-MIB
1.3.6.1.4.1.42229.1.2.13commonCORIANT-GROOVE-MIB
1.3.6.1.4.1.42229.1.2.13.40inletTemperatureCORIANT-GROOVE-MIB
1.3.6.1.4.1.42229.1.2.13.40.1inletTemperatureTableCORIANT-GROOVE-MIB
1.3.6.1.4.1.42229.1.2.13.40.1.1inletTemperatureEntryCORIANT-GROOVE-MIB
1.3.6.1.4.1.42229.1.2.13.40.1.1.4inletTemperatureMaxCORIANT-GROOVE-MIB