COMPELLENT-MIB :: scCtlrVoltageCritUprV

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCOMPELLENT-MIBscCtlrVoltageCritUprV

scCtlrVoltageCritUprV

Module: COMPELLENT-MIB

OID (symbolic): COMPELLENT-MIB::scCtlrVoltageCritUprV

OID (numeric): 1.3.6.1.4.1.16139.2.18.1.11

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: Controller Voltage Critical-level Upper Threshold

What is scCtlrVoltageCritUprV?

This Unsigned32 sets the critical-level upper voltage threshold for a specific controller voltage sensor. An admin treats a reading above this value as urgent, since an overvoltage condition this severe risks damaging controller components. This is the threshold that would justify an immediate hardware shutdown decision rather than continued monitoring.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.16139.2.18.1.11
snmpwalk -v2c -c public <target> COMPELLENT-MIB::scCtlrVoltageCritUprV

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.16139.2.18.1.11.1
snmpget -v2c -c public <target> COMPELLENT-MIB::scCtlrVoltageCritUprV.1

Start monitoring Dell Compellent Storage Center SAN array with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the COMPELLENT-MIB::scCtlrVoltageCritUprV OID value, configure state conditions and alerts, and monitor any Dell Compellent Storage Center SAN array from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.16139compellentEnterpriseCOMPELLENT-MIB
1.3.6.1.4.1.16139.2compellentObjectsCOMPELLENT-MIB
1.3.6.1.4.1.16139.2.18scCtlrVoltageTableCOMPELLENT-MIB
1.3.6.1.4.1.16139.2.18.1scCtlrVoltageEntryCOMPELLENT-MIB
1.3.6.1.4.1.16139.2.18.1.11scCtlrVoltageCritUprVCOMPELLENT-MIB