COMPELLENT-MIB :: scAlertCreateTime

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCOMPELLENT-MIBscAlertCreateTime

scAlertCreateTime

Module: COMPELLENT-MIB

OID (symbolic): COMPELLENT-MIB::scAlertCreateTime

OID (numeric): 1.3.6.1.4.1.16139.2.46.1.7

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Alert creation time

What is scAlertCreateTime?

This SnmpAdminString reports the creation time of a specific alert. An admin uses it to build a timeline of events when correlating an alert with other activity, such as a maintenance window or a related hardware trap. This timestamp is essential when reconstructing the sequence of events during a post-incident review.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.16139.2.46.1.7
snmpwalk -v2c -c public <target> COMPELLENT-MIB::scAlertCreateTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.16139.2.46.1.7.1
snmpget -v2c -c public <target> COMPELLENT-MIB::scAlertCreateTime.1

Start monitoring Dell Compellent Storage Center SAN array with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the COMPELLENT-MIB::scAlertCreateTime OID value, configure state conditions and alerts, and monitor any Dell Compellent Storage Center SAN array from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.16139compellentEnterpriseCOMPELLENT-MIB
1.3.6.1.4.1.16139.2compellentObjectsCOMPELLENT-MIB
1.3.6.1.4.1.16139.2.46scAlertTableCOMPELLENT-MIB
1.3.6.1.4.1.16139.2.46.1scAlertEntryCOMPELLENT-MIB
1.3.6.1.4.1.16139.2.46.1.7scAlertCreateTimeCOMPELLENT-MIB