CISCOSB-rlInterfaces :: rlIfCutThroughPriorityEnable

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCOSB-rlInterfacesrlIfCutThroughPriorityEnable

rlIfCutThroughPriorityEnable

Module: CISCOSB-rlInterfaces

OID (symbolic): CISCOSB-rlInterfaces::rlIfCutThroughPriorityEnable

OID (numeric): 1.3.6.1.4.1.9.6.1.101.54.27.1.1

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: Enable or disable cut-through for a priority for an interface.

What is rlIfCutThroughPriorityEnable?

This read-write TruthValue enables or disables cut-through switching for a given priority on a given interface, serving as the general per-interface, per-priority control described alongside the specific rlIfCutPriorityZero through Seven objects. It matters as the parameterized mechanism admins would use to configure cut-through per priority across many interfaces without eight separate scalar objects per port. For example, an SNMP management application would use this indexed object to programmatically toggle cut-through for a specific priority on a specific interface in a single set operation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.6.1.101.54.27.1.1
snmpwalk -v2c -c public <target> CISCOSB-rlInterfaces::rlIfCutThroughPriorityEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.6.1.101.54.27.1.1.1
snmpget -v2c -c public <target> CISCOSB-rlInterfaces::rlIfCutThroughPriorityEnable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9.6.1.101.54.27.1.1.1 s <value>

Start monitoring Cisco Small Business switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCOSB-rlInterfaces::rlIfCutThroughPriorityEnable OID value, configure state conditions and alerts, and monitor any Cisco Small Business switch from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.6otherEnterprisesCISCO-SMI
1.3.6.1.4.1.9.6.1ciscoSBCISCO-SMI
1.3.6.1.4.1.9.6.1.101switch001CISCOSB-MIB
1.3.6.1.4.1.9.6.1.101.54rlIfInterfacesCISCOSB-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.6.1.101.54.27rlIfCutThroughTableCISCOSB-rlInterfaces
1.3.6.1.4.1.9.6.1.101.54.27.1rlIfCutThroughEntryCISCOSB-rlInterfaces
1.3.6.1.4.1.9.6.1.101.54.27.1.1rlIfCutThroughPriorityEnableCISCOSB-rlInterfaces