CISCO-VRF-MIB :: cvVrfOperStatus

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-VRF-MIB › cvVrfOperStatus

cvVrfOperStatus

Module: CISCO-VRF-MIB

OID (symbolic): CISCO-VRF-MIB::cvVrfOperStatus

OID (numeric): 1.3.6.1.4.1.9.9.711.1.1.1.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Denotes whether a VRF is operational or not. A VRF is up(1) when at least one interface associated with the VRF, which ifOperStatus is up(1). A VRF is down(2) when:

a. There does not exist at least one interface whose ifOperStatus is up(1).

b. There are no interfaces associated with the VRF.

What is cvVrfOperStatus?

This read-only INTEGER reports whether a VRF instance is operational, showing up(1) when at least one of its associated interfaces has an ifOperStatus of up, and down(2) when none of its interfaces are up or no interfaces are assigned to it. An administrator monitors this value to confirm that a customer's or tenant's private routing domain still has a working path, since a VRF can silently go down(2) even while the physical router itself stays online. For example, if all interfaces mapped to VRF CUSTOMER-A go administratively down, cvVrfOperStatus for that VRF flips to down(2), flagging a loss of connectivity for that specific VRF.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.711.1.1.1.1.4
snmpwalk -v2c -c public <target> CISCO-VRF-MIB::cvVrfOperStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.711.1.1.1.1.4.1
snmpget -v2c -c public <target> CISCO-VRF-MIB::cvVrfOperStatus.1

Start monitoring Cisco provider-edge/enterprise router (VRF/VRF-Lite/vNET) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-VRF-MIB::cvVrfOperStatus OID value, configure state conditions and alerts, and monitor any Cisco provider-edge/enterprise router (VRF/VRF-Lite/vNET) from a single console.

How to Use in IPNetwork Monitor

Select a Cisco provider-edge/enterprise router (VRF/VRF-Lite/vNET) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cvVrfOperStatus into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. Denotes whether a VRF is operational or not. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'up', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.711ciscoVrfMIBCISCO-VRF-MIB
1.3.6.1.4.1.9.9.711.1ciscoVrfMIBObjectsCISCO-VRF-MIB
1.3.6.1.4.1.9.9.711.1.1cvVrfCISCO-VRF-MIB
1.3.6.1.4.1.9.9.711.1.1.1cvVrfTableCISCO-VRF-MIB
1.3.6.1.4.1.9.9.711.1.1.1.1cvVrfEntryCISCO-VRF-MIB
1.3.6.1.4.1.9.9.711.1.1.1.1.4cvVrfOperStatusCISCO-VRF-MIB