CISCO-VOICE-ANALOG-IF-MIB :: cvaIfStatusSignalErrors

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-VOICE-ANALOG-IF-MIBcvaIfStatusSignalErrors

cvaIfStatusSignalErrors

Module: CISCO-VOICE-ANALOG-IF-MIB

OID (symbolic): CISCO-VOICE-ANALOG-IF-MIB::cvaIfStatusSignalErrors

OID (numeric): 1.3.6.1.4.1.9.9.62.1.1.2.1.3

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: Accumulated number of signaling protocol errors that are detected in the interface since system startup.

What is cvaIfStatusSignalErrors?

This Counter32 accumulates the number of signaling protocol errors detected on the interface since system startup. An administrator watches this counter for a rising count as a sign of signaling problems on that specific analog voice port. For example, a steadily climbing count on one interface while others remain flat would point to a localized signaling issue on that port or its connected equipment.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.62.1.1.2.1.3
snmpwalk -v2c -c public <target> CISCO-VOICE-ANALOG-IF-MIB::cvaIfStatusSignalErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.62.1.1.2.1.3.1
snmpget -v2c -c public <target> CISCO-VOICE-ANALOG-IF-MIB::cvaIfStatusSignalErrors.1

Start monitoring Cisco ISR/voice gateways with analog FXS/FXO/E&M interfaces with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-VOICE-ANALOG-IF-MIB::cvaIfStatusSignalErrors OID value, configure state conditions and alerts, and monitor any Cisco ISR/voice gateways with analog FXS/FXO/E&M interfaces from a single console.

How to Use in IPNetwork Monitor

Select a Cisco ISR/voice gateway with an analog FXS/FXO/E&M interface as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cvaIfStatusSignalErrors into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the accumulated number of signaling protocol errors that are detected in the interface since system startup. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.62ciscoVoiceAnalogIfMIBCISCO-VOICE-ANALOG-IF-MIB
1.3.6.1.4.1.9.9.62.1cvaIfObjectsCISCO-VOICE-ANALOG-IF-MIB
1.3.6.1.4.1.9.9.62.1.1cvaIfGeneralObjectsCISCO-VOICE-ANALOG-IF-MIB
1.3.6.1.4.1.9.9.62.1.1.2cvaIfStatusTableCISCO-VOICE-ANALOG-IF-MIB
1.3.6.1.4.1.9.9.62.1.1.2.1cvaIfStatusEntryCISCO-VOICE-ANALOG-IF-MIB
1.3.6.1.4.1.9.9.62.1.1.2.1.3cvaIfStatusSignalErrorsCISCO-VOICE-ANALOG-IF-MIB