CISCO-STACK-MIB :: vlanPortIslPriorityVlans

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-STACK-MIBvlanPortIslPriorityVlans

vlanPortIslPriorityVlans

Module: CISCO-STACK-MIB

OID (symbolic): CISCO-STACK-MIB::vlanPortIslPriorityVlans

OID (numeric): 1.3.6.1.4.1.9.5.1.9.3.1.9

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: An indication of which Virtual LANs have a better dot1dStpPortPriority value. This object can be used to perform load balancing on Inter-Switch Links via spanning tree. An Inter-Switch Link has two dot1dStpPortPriority values which are shared by all the Virtual LANs on the link. The Virtual LANs indicated by this object have priority over the other Virtual LANs on the link.

This is an octet string value with bits set to indicate priority VLANs. It can be interpreted as a sum of f(x) as x goes from 0 to 1023, where f(x) = 0 for a VLAN x which does not have priority and f(x) = exp(2, x) for a VLAN x which has priority.

Setting the dot1dStpPortPriority value for any of the Virtual LANs indicated by this object causes the dot1dStpPortPriority value for all the Virtual LANs indicated by this object to be set to the same value.

Setting the dot1dStpPortPriority value for any other Virtual LAN causes the dot1dStpPortPriority value for all other Virtual LANs to be set to the same value.

What is vlanPortIslPriorityVlans?

This read-write bitmask object designates which VLANs get a better Spanning Tree port priority on an ISL trunk, enabling load balancing of traffic across redundant Inter-Switch Links.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.5.1.9.3.1.9
snmpwalk -v2c -c public <target> CISCO-STACK-MIB::vlanPortIslPriorityVlans

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.5.1.9.3.1.9.1
snmpget -v2c -c public <target> CISCO-STACK-MIB::vlanPortIslPriorityVlans.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9.5.1.9.3.1.9.1 s <value>

Start monitoring Cisco Catalyst switch (legacy/mid-generation) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-STACK-MIB::vlanPortIslPriorityVlans OID value, configure state conditions and alerts, and monitor any Cisco Catalyst switch (legacy/mid-generation) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.5workgroupCISCO-ES-STACK-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.5.1ciscoStackMIBCISCO-STACK-MIB
1.3.6.1.4.1.9.5.1.9vlanGrpCISCO-STACK-MIB
1.3.6.1.4.1.9.5.1.9.3vlanPortTableCISCO-STACK-MIB
1.3.6.1.4.1.9.5.1.9.3.1vlanPortEntryCISCO-STACK-MIB
1.3.6.1.4.1.9.5.1.9.3.1.9vlanPortIslPriorityVlansCISCO-STACK-MIB