radiusEnableAuthentication

Module: CISCO-STACK-MIB

OID (symbolic): CISCO-STACK-MIB::radiusEnableAuthentication

OID (numeric): 1.3.6.1.4.1.9.5.1.22.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Indicates whether the enable authentication using the RADIUS feature is enabled or disabled for Console and telnet sessions.

Setting this object to enabled(1), the enable authentication using RADIUS feature is enabled for both console and telnet sessions.

Setting this object to disabled(2), the enable authentication using RADIUS feature is disabled for both console and telnet sessions.

Setting this object to enabledForTelnetOnly(3), the enable authentication using RADIUS feature is enabled only for telnet sessions, but disabled for console sessions.

Setting this object to enabledForConsoleOnly(4), the enable authentication using RADIUS feature is enabled only for console sessions, but disabled for telnet sessions.

This object is deprecated and replaced by cacPriorityTable in CISCO-AAA-CLIENT-MIB.

What is radiusEnableAuthentication?

Enables or disables RADIUS-based authentication required to enter privileged (enable) mode for console and Telnet sessions.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.5.1.22.2
snmpwalk -v2c -c public <target> CISCO-STACK-MIB::radiusEnableAuthentication

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.5.1.22.2.1
snmpget -v2c -c public <target> CISCO-STACK-MIB::radiusEnableAuthentication.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9.5.1.22.2.1 i <value>

Start monitoring Cisco Catalyst switch (legacy/mid-generation) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-STACK-MIB::radiusEnableAuthentication OID value, configure state conditions and alerts, and monitor any Cisco Catalyst switch (legacy/mid-generation) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.5workgroupCISCO-ES-STACK-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.5.1ciscoStackMIBCISCO-STACK-MIB
1.3.6.1.4.1.9.5.1.22radiusGrpCISCO-STACK-MIB
1.3.6.1.4.1.9.5.1.22.2radiusEnableAuthenticationCISCO-STACK-MIB