CISCO-P2P-IF-MIB :: cp2pIfStatsInCrcErrors

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-P2P-IF-MIB › cp2pIfStatsInCrcErrors

cp2pIfStatsInCrcErrors

Module: CISCO-P2P-IF-MIB

OID (symbolic): CISCO-P2P-IF-MIB::cp2pIfStatsInCrcErrors

OID (numeric): 1.3.6.1.4.1.9.9.668.1.1.2.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: Accumulated number of CRC errors that are detected on the received packets via the Point to Point interface since system startup.

What is cp2pIfStatsInCrcErrors?

Reports the cumulative count of CRC errors detected on packets received via the point-to-point interface since system startup.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.668.1.1.2.1.1
snmpwalk -v2c -c public <target> CISCO-P2P-IF-MIB::cp2pIfStatsInCrcErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.668.1.1.2.1.1.1
snmpget -v2c -c public <target> CISCO-P2P-IF-MIB::cp2pIfStatsInCrcErrors.1

Start monitoring Cisco router with serial/SONET-SDH point-to-point interface with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-P2P-IF-MIB::cp2pIfStatsInCrcErrors OID value, configure state conditions and alerts, and monitor any Cisco router with serial/SONET-SDH point-to-point interface from a single console.

How to Use in IPNetwork Monitor

Select a Cisco router with serial/SONET-SDH point-to-point interface as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cp2pIfStatsInCrcErrors into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the accumulated number of CRC errors that are detected on the received packets via the Point to Point interface since system startup. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.668ciscoP2PIfMIBCISCO-P2P-IF-MIB
1.3.6.1.4.1.9.9.668.1ciscoP2PIfMIBObjectsCISCO-P2P-IF-MIB
1.3.6.1.4.1.9.9.668.1.1cp2pIfGeneralObjectsCISCO-P2P-IF-MIB
1.3.6.1.4.1.9.9.668.1.1.2cp2pIfStatsTableCISCO-P2P-IF-MIB
1.3.6.1.4.1.9.9.668.1.1.2.1cp2pIfStatsEntryCISCO-P2P-IF-MIB
1.3.6.1.4.1.9.9.668.1.1.2.1.1cp2pIfStatsInCrcErrorsCISCO-P2P-IF-MIB