CISCO-NETINT-MIB :: cniThrottleCount

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-NETINT-MIB › cniThrottleCount

cniThrottleCount

Module: CISCO-NETINT-MIB

OID (symbolic): CISCO-NETINT-MIB::cniThrottleCount

OID (numeric): 1.3.6.1.4.1.9.9.490.1.1.1.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This object indicates the number of times network interrupt throttle has become active.

What is cniThrottleCount?

A read-only counter reporting how many times the device's network interrupt throttling mechanism has activated, indicating periods of high interrupt load.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.490.1.1.1.1.1
snmpwalk -v2c -c public <target> CISCO-NETINT-MIB::cniThrottleCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.490.1.1.1.1.1.1
snmpget -v2c -c public <target> CISCO-NETINT-MIB::cniThrottleCount.1

Start monitoring Cisco router (CPU-protection/interrupt-throttling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-NETINT-MIB::cniThrottleCount OID value, configure state conditions and alerts, and monitor any Cisco router (CPU-protection/interrupt-throttling) from a single console.

How to Use in IPNetwork Monitor

Select a Cisco router (CPU-protection/interrupt-throttling) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cniThrottleCount into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This object indicates the number of times network interrupt throttle has become active. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.490ciscoNetintMIBCISCO-NETINT-MIB
1.3.6.1.4.1.9.9.490.1ciscoNetintMIBObjectsCISCO-NETINT-MIB
1.3.6.1.4.1.9.9.490.1.1cniThrottleCISCO-NETINT-MIB
1.3.6.1.4.1.9.9.490.1.1.1cniThrottleTableCISCO-NETINT-MIB
1.3.6.1.4.1.9.9.490.1.1.1.1cniThrottleEntryCISCO-NETINT-MIB
1.3.6.1.4.1.9.9.490.1.1.1.1.1cniThrottleCountCISCO-NETINT-MIB