CISCO-IPSEC-FLOW-MONITOR-MIB :: cipSecEndPtRemoteAddr2

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-IPSEC-FLOW-MONITOR-MIBcipSecEndPtRemoteAddr2

cipSecEndPtRemoteAddr2

Module: CISCO-IPSEC-FLOW-MONITOR-MIB

OID (symbolic): CISCO-IPSEC-FLOW-MONITOR-MIB::cipSecEndPtRemoteAddr2

OID (numeric): 1.3.6.1.4.1.9.9.171.1.3.3.1.11

Node type: OBJECT-TYPE

Type: IPSIpAddress

Access: read-only

Description: The remote Endpoint's second IP address specification.

If the remote Endpoint type is single IP address, then this is the value of the IP address.

If the remote Endpoint type is IP subnet, then this is the value of the subnet mask.

If the remote Endpoint type is IP address range, then this is the value of ending IP address of the range.

What is cipSecEndPtRemoteAddr2?

This read-only value reports the second IP address component of the remote endpoint (such as a subnet mask or range end address), with its meaning depending on the remote endpoint type.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.171.1.3.3.1.11
snmpwalk -v2c -c public <target> CISCO-IPSEC-FLOW-MONITOR-MIB::cipSecEndPtRemoteAddr2

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.171.1.3.3.1.11.1
snmpget -v2c -c public <target> CISCO-IPSEC-FLOW-MONITOR-MIB::cipSecEndPtRemoteAddr2.1

Start monitoring Cisco router/firewall/VPN concentrator terminating IPsec tunnels with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-IPSEC-FLOW-MONITOR-MIB::cipSecEndPtRemoteAddr2 OID value, configure state conditions and alerts, and monitor any Cisco router/firewall/VPN concentrator terminating IPsec tunnels from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.171ciscoIpSecFlowMonitorMIBCISCO-IPSEC-FLOW-MONITOR-MIB
1.3.6.1.4.1.9.9.171.1cipSecMIBObjectsCISCO-IPSEC-FLOW-MONITOR-MIB
1.3.6.1.4.1.9.9.171.1.3cipSecPhaseTwoCISCO-IPSEC-FLOW-MONITOR-MIB
1.3.6.1.4.1.9.9.171.1.3.3cipSecEndPtTableCISCO-IPSEC-FLOW-MONITOR-MIB
1.3.6.1.4.1.9.9.171.1.3.3.1cipSecEndPtEntryCISCO-IPSEC-FLOW-MONITOR-MIB
1.3.6.1.4.1.9.9.171.1.3.3.1.11cipSecEndPtRemoteAddr2CISCO-IPSEC-FLOW-MONITOR-MIB