CISCO-EPC-GATEWAY-MIB :: cegCongestionIncomingReqDrops

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-EPC-GATEWAY-MIBcegCongestionIncomingReqDrops

cegCongestionIncomingReqDrops

Module: CISCO-EPC-GATEWAY-MIB

OID (symbolic): CISCO-EPC-GATEWAY-MIB::cegCongestionIncomingReqDrops

OID (numeric): 1.3.6.1.4.1.9.9.731.1.1.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This object represents the total number of incoming calls dropped at the gateway.

This counter is incremented when the gateway receives an incoming call request at high congestion level, and the request is dropped.

What is cegCongestionIncomingReqDrops?

Counts the total number of incoming call requests that the gateway has dropped because they arrived while the gateway was experiencing high congestion.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.731.1.1.1.1
snmpwalk -v2c -c public <target> CISCO-EPC-GATEWAY-MIB::cegCongestionIncomingReqDrops

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.731.1.1.1.1.1
snmpget -v2c -c public <target> CISCO-EPC-GATEWAY-MIB::cegCongestionIncomingReqDrops.1

Start monitoring Cisco ASR/StarOS gateway platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-EPC-GATEWAY-MIB::cegCongestionIncomingReqDrops OID value, configure state conditions and alerts, and monitor any Cisco ASR/StarOS gateway platforms from a single console.

How to Use in IPNetwork Monitor

Select a Cisco ASR/StarOS gateway platform as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cegCongestionIncomingReqDrops into the Find box to locate it in the OID tree, then select it and click OK. This object represents the total number of incoming calls dropped at the gateway. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.731ciscoEpcGatewayMIBCISCO-EPC-GATEWAY-MIB
1.3.6.1.4.1.9.9.731.1ciscoEpcGatewayMIBObjectsCISCO-EPC-GATEWAY-MIB
1.3.6.1.4.1.9.9.731.1.1ciscoEpcGatewayStatisticsCISCO-EPC-GATEWAY-MIB
1.3.6.1.4.1.9.9.731.1.1.1cegOverloadProtectionStatsCISCO-EPC-GATEWAY-MIB
1.3.6.1.4.1.9.9.731.1.1.1.1cegCongestionIncomingReqDropsCISCO-EPC-GATEWAY-MIB