CISCO-DOT11-QOS-MIB :: cdot11QosQueuePeakSize

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-DOT11-QOS-MIB › cdot11QosQueuePeakSize

cdot11QosQueuePeakSize

Module: CISCO-DOT11-QOS-MIB

OID (symbolic): CISCO-DOT11-QOS-MIB::cdot11QosQueuePeakSize

OID (numeric): 1.3.6.1.4.1.9.9.416.1.2.1.1.3

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This is the peak QoS priority queue size for this queue.

What is cdot11QosQueuePeakSize?

This read-only object reports the peak (highest observed) size reached by a specific QoS priority transmit queue.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.416.1.2.1.1.3
snmpwalk -v2c -c public <target> CISCO-DOT11-QOS-MIB::cdot11QosQueuePeakSize

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.416.1.2.1.1.3.1
snmpget -v2c -c public <target> CISCO-DOT11-QOS-MIB::cdot11QosQueuePeakSize.1

Start monitoring Cisco Wireless LAN access points, bridges, and switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-DOT11-QOS-MIB::cdot11QosQueuePeakSize OID value, configure state conditions and alerts, and monitor any Cisco Wireless LAN access points, bridges, and switches from a single console.

How to Use in IPNetwork Monitor

Select a Cisco Wireless LAN access point, bridge, or switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cdot11QosQueuePeakSize into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This is the peak QoS priority queue size for this queue. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the value climbs close to a level you consider a practical ceiling for this device, since a rising peak often signals sustained load growth worth planning capacity around. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.416ciscoDot11QosMIBCISCO-DOT11-QOS-MIB
1.3.6.1.4.1.9.9.416.1ciscoDot11QosMIBObjectsCISCO-DOT11-QOS-MIB
1.3.6.1.4.1.9.9.416.1.2ciscoDot11QosQueueCISCO-DOT11-QOS-MIB
1.3.6.1.4.1.9.9.416.1.2.1cdot11QosQueueTableCISCO-DOT11-QOS-MIB
1.3.6.1.4.1.9.9.416.1.2.1.1cdot11QosQueueEntryCISCO-DOT11-QOS-MIB
1.3.6.1.4.1.9.9.416.1.2.1.1.3cdot11QosQueuePeakSizeCISCO-DOT11-QOS-MIB