CISCO-CIPTCPIP-MIB :: cipIpInReceives

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-CIPTCPIP-MIBcipIpInReceives

cipIpInReceives

Module: CISCO-CIPTCPIP-MIB

OID (symbolic): CISCO-CIPTCPIP-MIB::cipIpInReceives

OID (numeric): 1.3.6.1.4.1.9.9.32.1.1.1.1.4

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The total number of input datagrams received from interfaces, including those received in error, for this IP Address instance.

What is cipIpInReceives?

Counts the total number of IP datagrams received on this interface's interfaces, including ones that had errors, providing a measure of inbound IP traffic volume.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.32.1.1.1.1.4
snmpwalk -v2c -c public <target> CISCO-CIPTCPIP-MIB::cipIpInReceives

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.32.1.1.1.1.4.1
snmpget -v2c -c public <target> CISCO-CIPTCPIP-MIB::cipIpInReceives.1

Start monitoring Cisco CMCC/CIP mainframe channel connection board (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-CIPTCPIP-MIB::cipIpInReceives OID value, configure state conditions and alerts, and monitor any Cisco CMCC/CIP mainframe channel connection board (legacy) from a single console.

How to Use in IPNetwork Monitor

Select a Cisco CMCC/CIP mainframe channel connection board (legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cipIpInReceives into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total number of input datagrams received from interfaces, including those received in error, for this IP Address instance. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.32ciscoCipTcpIpMIBCISCO-CIPTCPIP-MIB
1.3.6.1.4.1.9.9.32.1cipTcpIpObjectsCISCO-CIPTCPIP-MIB
1.3.6.1.4.1.9.9.32.1.1cipIpObjectsCISCO-CIPTCPIP-MIB
1.3.6.1.4.1.9.9.32.1.1.1cipIpTableCISCO-CIPTCPIP-MIB
1.3.6.1.4.1.9.9.32.1.1.1.1cipIpEntryCISCO-CIPTCPIP-MIB
1.3.6.1.4.1.9.9.32.1.1.1.1.4cipIpInReceivesCISCO-CIPTCPIP-MIB