coCdlRxHeaderCRCError

Module: CISCO-CDL-MIB

OID (symbolic): CISCO-CDL-MIB::coCdlRxHeaderCRCError

OID (numeric): 1.3.6.1.4.1.9.10.88.1.1.1.1.10

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of CDL frames received with CDL Header CRC errors.

This object represents the lower word value of the counter associated with the number of CDL header CRC errors encountered in the receive direction.

NOTE: The object coCdlRxHeaderCRCErrorOverflow contains the higher 32 bits of this counter value. SNMP v2c or v3 managers can use the coCdlHCRxHeaderCRCError object directly which is a 64 bit counter.

What is coCdlRxHeaderCRCError?

Counts the number of received CDL frames with header CRC errors on this interface (lower 32 bits of a wrapping counter).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.10.88.1.1.1.1.10
snmpwalk -v2c -c public <target> CISCO-CDL-MIB::coCdlRxHeaderCRCError

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.10.88.1.1.1.1.10.1
snmpget -v2c -c public <target> CISCO-CDL-MIB::coCdlRxHeaderCRCError.1

Start monitoring Cisco optical/Ethernet transport node (Converged Data Link) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-CDL-MIB::coCdlRxHeaderCRCError OID value, configure state conditions and alerts, and monitor any Cisco optical/Ethernet transport node (Converged Data Link) from a single console.

How to Use in IPNetwork Monitor

Select a Cisco optical/Ethernet transport node (Converged Data Link) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type coCdlRxHeaderCRCError into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of CDL frames received with CDL Header CRC errors. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.10ciscoExperimentCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.10.88ciscoCdlMIBCISCO-CDL-MIB
1.3.6.1.4.1.9.10.88.1coCdlMIBObjectsCISCO-CDL-MIB
1.3.6.1.4.1.9.10.88.1.1coCdlBaseGroupCISCO-CDL-MIB
1.3.6.1.4.1.9.10.88.1.1.1coCdlIntfTableCISCO-CDL-MIB
1.3.6.1.4.1.9.10.88.1.1.1.1coCdlIntfEntryCISCO-CDL-MIB
1.3.6.1.4.1.9.10.88.1.1.1.1.10coCdlRxHeaderCRCErrorCISCO-CDL-MIB