Description: This notification is sent when the value of the hop-by-hop forward defect indication (FDI-H), hop-by-hop backward defect indication (BDI-H), or end-to-end (aggregate path) forward defect indication (FDI-E) bit received on an interface changes.
To minimize the probability of prematurely reacting to momentary signal variations, a soak time may be incorporated into the notification in the following manner. A notification is generated after a defect is first detected, when the defect persists for a period of time that exceeds the set soak interval specified by coCdlDefectIndSetSoakInterval. A notification is generated after a defect stops being detected, when the defect does not appear over a period of time that exceeds the clear soak interval specified by coCdlDefectIndClearSoakInterval.
When changes in CDL defect indications are received for multiple interfaces within a short time span, notifications should be deferred so that each notification is generated at least one coCdlDINotifyThrottleInterval after the previous notification.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' CISCO-CDL-MIB::coCdlRxAggDefectIndChange snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.9.10.88.0.1
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:53607->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (184152423) 21 days, 7:32:04.23 SNMPv2-MIB::snmpTrapOID.0 = OID: CISCO-CDL-MIB::coCdlRxAggDefectIndChange
Start monitoring Cisco optical/Ethernet transport node (Converged Data Link) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-CDL-MIB::coCdlRxAggDefectIndChange OID value, configure state conditions and alerts, and monitor any Cisco optical/Ethernet transport node (Converged Data Link) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.10 | ciscoExperiment | CISCO-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.10.88 | ciscoCdlMIB | CISCO-CDL-MIB |
| 1.3.6.1.4.1.9.10.88.0 | coCdlMIBNotifications | CISCO-CDL-MIB |
| 1.3.6.1.4.1.9.10.88.0.1 | coCdlRxAggDefectIndChange | CISCO-CDL-MIB |