CISCO-CDL-MIB :: coCdlRxAggDefectIndChange

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-CDL-MIB › coCdlRxAggDefectIndChange

coCdlRxAggDefectIndChange

Module: CISCO-CDL-MIB

OID (symbolic): CISCO-CDL-MIB::coCdlRxAggDefectIndChange

OID (numeric): 1.3.6.1.4.1.9.10.88.0.1

Node type: NOTIFICATION-TYPE

Description: This notification is sent when the value of the hop-by-hop forward defect indication (FDI-H), hop-by-hop backward defect indication (BDI-H), or end-to-end (aggregate path) forward defect indication (FDI-E) bit received on an interface changes.

To minimize the probability of prematurely reacting to momentary signal variations, a soak time may be incorporated into the notification in the following manner. A notification is generated after a defect is first detected, when the defect persists for a period of time that exceeds the set soak interval specified by coCdlDefectIndSetSoakInterval. A notification is generated after a defect stops being detected, when the defect does not appear over a period of time that exceeds the clear soak interval specified by coCdlDefectIndClearSoakInterval.

When changes in CDL defect indications are received for multiple interfaces within a short time span, notifications should be deferred so that each notification is generated at least one coCdlDINotifyThrottleInterval after the previous notification.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' CISCO-CDL-MIB::coCdlRxAggDefectIndChange
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.9.10.88.0.1

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:53607->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (184152423) 21 days, 7:32:04.23
  SNMPv2-MIB::snmpTrapOID.0 = OID: CISCO-CDL-MIB::coCdlRxAggDefectIndChange

Start monitoring Cisco optical/Ethernet transport node (Converged Data Link) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-CDL-MIB::coCdlRxAggDefectIndChange OID value, configure state conditions and alerts, and monitor any Cisco optical/Ethernet transport node (Converged Data Link) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.10ciscoExperimentCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.10.88ciscoCdlMIBCISCO-CDL-MIB
1.3.6.1.4.1.9.10.88.0coCdlMIBNotificationsCISCO-CDL-MIB
1.3.6.1.4.1.9.10.88.0.1coCdlRxAggDefectIndChangeCISCO-CDL-MIB