CISCO-ATM-RM-MIB :: cgrPerVcqRmHierarchicalSchedulingMode

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-ATM-RM-MIBcgrPerVcqRmHierarchicalSchedulingMode

cgrPerVcqRmHierarchicalSchedulingMode

Module: CISCO-ATM-RM-MIB

OID (symbolic): CISCO-ATM-RM-MIB::cgrPerVcqRmHierarchicalSchedulingMode

OID (numeric): 1.3.6.1.4.1.9.10.10.1.9.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: On a Catalyst8540 MSR, the user can define Hierarchical VP-Tunnels. Each such tunnel has its own dedicated scheduler, programmed to output data at a configurable maximum rate.

Therefore, the overall output of the Hierarchical VP-tunnel is rate-limited. In addition, Virtual Circuits of different service categories can traverse through such a tunnel, and each of these Virtual Circuits are guaranteed their individual contracted bandwidth agreement.

This object must be set to enabled before any Hierarchical VP-tunnels can be defined on the device.

Any setting of this variable requires a reload of the device to be effective.

Setting this object to enabled will cause the software to initialize the additional schedulers needed by the Hierarchical VP-Tunnels. Other limited scheduler resources are therefore used by a larger number of schedulers (as compared to the case when Hierarchical Scheduling is disabled on the device). This may result in fewer number of connections passing Connection Admission Control.

This object is therefore provided so that the user can make an informed decision as to whether Hierarchical Scheduling is to be used.

This object is supported only on the Catalyst8540MSR platform.

What is cgrPerVcqRmHierarchicalSchedulingMode?

Read-write control for enabling hierarchical VP-tunnel scheduling on a Catalyst 8540 MSR, where each tunnel has its own rate-limited output scheduler.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.10.10.1.9.3
snmpwalk -v2c -c public <target> CISCO-ATM-RM-MIB::cgrPerVcqRmHierarchicalSchedulingMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.10.10.1.9.3.1
snmpget -v2c -c public <target> CISCO-ATM-RM-MIB::cgrPerVcqRmHierarchicalSchedulingMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9.10.10.1.9.3.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cgrPerVcqRmHierarchicalSchedulingMode.1

Start monitoring Cisco ATM switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-ATM-RM-MIB::cgrPerVcqRmHierarchicalSchedulingMode OID value, configure state conditions and alerts, and monitor any Cisco ATM switches from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.10ciscoExperimentCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.10.10ciscoAtmRmMIBCISCO-ATM-RM-MIB
1.3.6.1.4.1.9.10.10.1ciscoAtmRmMIBObjectsCISCO-ATM-RM-MIB
1.3.6.1.4.1.9.10.10.1.9ciscoCgrPerVcqAtmRmSwitchCISCO-ATM-RM-MIB
1.3.6.1.4.1.9.10.10.1.9.3cgrPerVcqRmHierarchicalSchedulingModeCISCO-ATM-RM-MIB