CISCO-APS-MIB :: cApsConfigMode

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-APS-MIB › cApsConfigMode

cApsConfigMode

Module: CISCO-APS-MIB

OID (symbolic): CISCO-APS-MIB::cApsConfigMode

OID (numeric): 1.3.6.1.4.1.9.10.71.1.1.2.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-create

Description: The architecture of the APS group.

onePlusOne

The 1+1 architecture permanently bridges the working line to the protection line.

oneToN

The 1:n architecture allows one protection channel to protect up to n working channels. When a fault is detected on one of the n working channels that channel is bridged over the protection channel.

onePlusOneCompatible

This refers to 1 + 1 bidirectional switching compatible with 1:n bidirectional switching as specified in ITU-T Recommendation G.783 (04/97) section A.3.4.1. Since this mode necessitates bidirectional switching, cApsConfigDirection must be set to bidirectional whenever onePlusOneCompatible is set.

onePlusOneOptimized

This refers to 1 + 1 bidirectional switching optimized for a network using predominantly 1 + 1 bidirectional switching as specified in ITU-T Recommendation G.783 (04/97) section B.1. Since this mode necessitates bidirectional switching, cApsConfigDirection must be set to bidirectional whenever onePlusOneOptimized is set.

This object may not be modified if the associated cApsConfigRowStatus object is equal to active(1).

What is cApsConfigMode?

This selects the protection architecture for this APS group from four options: onePlusOne, which permanently bridges the working line to the protection line; oneToN, which lets a single protection channel back up to n separate working channels, bridging over the protection line whichever working channel currently has a fault; and two 1+1 compatibility/optimization variants for interoperability or efficiency. This choice fundamentally shapes the group's other configuration requirements -- for instance, oneToN mode requires the group's revert setting (cApsConfigRevert) to be revertive, a constraint that doesn't apply to onePlusOne. For example, choosing oneToN for a group protecting four working channels with a single shared protection line means only one of those four can actually be in a failed-over state at any given time, since there's just one protection channel to go around.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.10ciscoExperimentCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.10.71cApsMIBCISCO-APS-MIB
1.3.6.1.4.1.9.10.71.1cApsMIBObjectsCISCO-APS-MIB
1.3.6.1.4.1.9.10.71.1.1cApsConfigCISCO-APS-MIB
1.3.6.1.4.1.9.10.71.1.1.2cApsConfigTableCISCO-APS-MIB
1.3.6.1.4.1.9.10.71.1.1.2.1cApsConfigEntryCISCO-APS-MIB
1.3.6.1.4.1.9.10.71.1.1.2.1.3cApsConfigModeCISCO-APS-MIB