CIRCUIT-IF-MIB :: ciIfNumActive

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CIRCUIT-IF-MIB › ciIfNumActive

ciIfNumActive

Module: CIRCUIT-IF-MIB

OID (symbolic): CIRCUIT-IF-MIB::ciIfNumActive

OID (numeric): 1.3.6.1.2.1.94.1.4

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: The number of active rows in ciCircuitTable.

What is ciIfNumActive?

This Gauge32 reports the current count of circuits in ciCircuitTable that are in the active(1) state, giving a single at-a-glance number for how many provisioned circuits are actually in service on this device right now. An admin can trend this value over time to spot unexpected drops (circuits going down or being deprovisioned en masse) without needing to enumerate the whole table. For example, a device expected to run 24 active circuits that suddenly reports 20 here signals four circuits have dropped out of active status and warrants investigation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.94.1.4
snmpwalk -v2c -c public <target> CIRCUIT-IF-MIB::ciIfNumActive

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.94.1.4.1
snmpget -v2c -c public <target> CIRCUIT-IF-MIB::ciIfNumActive.1

Start monitoring Routers/switches provisioning ATM, Frame Relay, or SONET circuits with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIRCUIT-IF-MIB::ciIfNumActive OID value, configure state conditions and alerts, and monitor any Routers/switches provisioning ATM, Frame Relay, or SONET circuits from a single console.

How to Use in IPNetwork Monitor

Select a Routers/switches provisioning ATM, Frame Relay, or SONET circuit as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type ciIfNumActive into the Find box to locate it in the OID tree, then select it and click OK. The number of active rows in ciCircuitTable. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAPERTUS-NPG-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.94circuitIfMIBCIRCUIT-IF-MIB
1.3.6.1.2.1.94.1ciObjectsCIRCUIT-IF-MIB
1.3.6.1.2.1.94.1.4ciIfNumActiveCIRCUIT-IF-MIB