CIENA-CES-OSPF-MIB :: cienaCesOspfCalcMaxDelay

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CIENA-CES-OSPF-MIB › cienaCesOspfCalcMaxDelay

cienaCesOspfCalcMaxDelay

Module: CIENA-CES-OSPF-MIB

OID (symbolic): CIENA-CES-OSPF-MIB::cienaCesOspfCalcMaxDelay

OID (numeric): 1.3.6.1.4.1.1271.2.1.19.1.1.10

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: The maximum delay before the routing table is recalculated following a change to the Link State Database. (Recalculation is delayed to reduce the frequency of recalculations of the routing table).

This parameter has units of milliseconds. A value of 0 indicates that a routing calculation will immediately follow an update to the database.

What is cienaCesOspfCalcMaxDelay?

This read-only Unsigned32, in milliseconds, reports the maximum delay the router will wait before recalculating its routing table following a Link State Database change, per its description, with a value of 0 meaning recalculation happens immediately on every update. This delay exists specifically to batch multiple near-simultaneous topology changes into a single SPF run rather than recalculating routes on every individual LSA, trading a small amount of convergence latency for reduced CPU load during periods of rapid topology churn. An engineer tuning convergence speed versus CPU load on a router in a large, frequently-changing OSPF domain would check this value to understand the deliberate trade-off currently configured between fast reaction and computation efficiency.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.19.1.1.10
snmpwalk -v2c -c public <target> CIENA-CES-OSPF-MIB::cienaCesOspfCalcMaxDelay

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.19.1.1.10.1
snmpget -v2c -c public <target> CIENA-CES-OSPF-MIB::cienaCesOspfCalcMaxDelay.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-OSPF-MIB::cienaCesOspfCalcMaxDelay OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.19cienaCesOspfMIBCIENA-CES-OSPF-MIB
1.3.6.1.4.1.1271.2.1.19.1cienaCesOspfMIBObjectsCIENA-CES-OSPF-MIB
1.3.6.1.4.1.1271.2.1.19.1.1cienaCesOspfGeneralGroupCIENA-CES-OSPF-MIB
1.3.6.1.4.1.1271.2.1.19.1.1.10cienaCesOspfCalcMaxDelayCIENA-CES-OSPF-MIB