CBS-HARDWARE-MIB :: cbsHwSystemChassisTemp

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCBS-HARDWARE-MIBcbsHwSystemChassisTemp

cbsHwSystemChassisTemp

Module: CBS-HARDWARE-MIB

OID (symbolic): CBS-HARDWARE-MIB::cbsHwSystemChassisTemp

OID (numeric): 1.3.6.1.4.1.6848.2.1.2.3

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The temperature of the chassis air flow as measured at the upper fan tray.

What is cbsHwSystemChassisTemp?

This read-only object reports the current temperature measured at the chassis exhaust air outlet (upper fan tray area) of a CBS hardware system, with values ranging from -25 to 50 degrees Celsius. It provides real-time thermal monitoring of the primary equipment airflow path. Operators use this metric to prevent overheating, trigger cooling fan increases, or generate alarms when temperature thresholds are exceeded.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6848.2.1.2.3
snmpwalk -v2c -c public <target> CBS-HARDWARE-MIB::cbsHwSystemChassisTemp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6848.2.1.2.3.1
snmpget -v2c -c public <target> CBS-HARDWARE-MIB::cbsHwSystemChassisTemp.1

Start monitoring Crossbeam Systems XOS security appliance chassis (not Cisco, despite the module description) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CBS-HARDWARE-MIB::cbsHwSystemChassisTemp OID value, configure state conditions and alerts, and monitor any Crossbeam Systems XOS security appliance chassis (not Cisco, despite the module description) from a single console.

How to Use in IPNetwork Monitor

Select a Crossbeam Systems XOS security appliance chassis as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cbsHwSystemChassisTemp into the Find box to locate it in the OID tree, then select it and click OK. It reports the temperature of the chassis air flow as measured at the upper fan tray, in degrees Celsius. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds 45°C, since sustained high chassis temperature often precedes thermal shutdown or hardware degradation. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6848crossbeamSystemsCROSSBEAM-SYSTEMS-MIB
1.3.6.1.4.1.6848.2cbsMgmtCROSSBEAM-SYSTEMS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6848.2.1cbsHardwareCBS-HARDWARE-MIB
1.3.6.1.4.1.6848.2.1.2cbsHwSystemStatusCBS-HARDWARE-MIB
1.3.6.1.4.1.6848.2.1.2.3cbsHwSystemChassisTempCBS-HARDWARE-MIB