CBS-HARDWARE-MIB :: cbsHwModule125Voltage

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCBS-HARDWARE-MIBcbsHwModule125Voltage

cbsHwModule125Voltage

Module: CBS-HARDWARE-MIB

OID (symbolic): CBS-HARDWARE-MIB::cbsHwModule125Voltage

OID (numeric): 1.3.6.1.4.1.6848.2.1.6.1.20

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Current voltage level of the 1.25 volt power supply. This number is in 1/100ths of a volt and the ideal value of 1.25 volts will be read as 125. For modules that don't support it, a special invalid value of 10000 will be returned.

What is cbsHwModule125Voltage?

This gauge measures the current output voltage of the 1.25-volt power supply rail in a hardware module, with values expressed as hundredths of a volt (so 125 represents the ideal 1.25 volts). An invalid value of 10000 is returned for modules that do not support this measurement. Power system engineers monitor this to ensure stable voltage delivery and detect impending power supply failures.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6848.2.1.6.1.20
snmpwalk -v2c -c public <target> CBS-HARDWARE-MIB::cbsHwModule125Voltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6848.2.1.6.1.20.1
snmpget -v2c -c public <target> CBS-HARDWARE-MIB::cbsHwModule125Voltage.1

Start monitoring Crossbeam Systems XOS security appliance chassis (not Cisco, despite the module description) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CBS-HARDWARE-MIB::cbsHwModule125Voltage OID value, configure state conditions and alerts, and monitor any Crossbeam Systems XOS security appliance chassis (not Cisco, despite the module description) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6848crossbeamSystemsCROSSBEAM-SYSTEMS-MIB
1.3.6.1.4.1.6848.2cbsMgmtCROSSBEAM-SYSTEMS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6848.2.1cbsHardwareCBS-HARDWARE-MIB
1.3.6.1.4.1.6848.2.1.6cbsHwModuleStatusTableCBS-HARDWARE-MIB
1.3.6.1.4.1.6848.2.1.6.1cbsHwModuleStatusEntryCBS-HARDWARE-MIB
1.3.6.1.4.1.6848.2.1.6.1.20cbsHwModule125VoltageCBS-HARDWARE-MIB