CAMBIUM-PTP800-MIB :: rFUTxPowerMax

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCAMBIUM-PTP800-MIBrFUTxPowerMax

rFUTxPowerMax

Module: CAMBIUM-PTP800-MIB

OID (symbolic): CAMBIUM-PTP800-MIB::rFUTxPowerMax

OID (numeric): 1.3.6.1.4.1.17713.8.23.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Maximum transmitter power level, in 10ths of dBm

What is rFUTxPowerMax?

This reports the maximum transmitter power level the RFU hardware supports, in tenths of dBm. It defines the high end of the range within which ATPC or manual power settings can operate, working alongside Maximum Transmit Power to cap actual output.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.17713.8.23.5
snmpwalk -v2c -c public <target> CAMBIUM-PTP800-MIB::rFUTxPowerMax

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.17713.8.23.5.1
snmpget -v2c -c public <target> CAMBIUM-PTP800-MIB::rFUTxPowerMax.1

Start monitoring Cambium Networks PTP 800 licensed microwave wireless bridge with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CAMBIUM-PTP800-MIB::rFUTxPowerMax OID value, configure state conditions and alerts, and monitor any Cambium Networks PTP 800 licensed microwave wireless bridge from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.17713cambiumCAMBIUM-PMP80211-MIB
Numeric OIDNameModule
1.3.6.1.4.1.17713.8ptp800CAMBIUM-PTP800-MIB
1.3.6.1.4.1.17713.8.23rfuCAMBIUM-PTP800-MIB
1.3.6.1.4.1.17713.8.23.5rFUTxPowerMaxCAMBIUM-PTP800-MIB