CAMBIUM-PTP800-MIB :: rFUTxPowerDegradedAlarm

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCAMBIUM-PTP800-MIBrFUTxPowerDegradedAlarm

rFUTxPowerDegradedAlarm

Module: CAMBIUM-PTP800-MIB

OID (symbolic): CAMBIUM-PTP800-MIB::rFUTxPowerDegradedAlarm

OID (numeric): 1.3.6.1.4.1.17713.8.23.23

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Indicates when the current transmit power is more than 3 dB below or more than 3 dB above the correct transmit power.

What is rFUTxPowerDegradedAlarm?

This alarm fires when the current transmit power is more than 3 dB below or more than 3 dB above the correct transmit power ('degraded'). It flags a power level that is out of tolerance without being a total transmitter failure, distinguishing it from rFUTxPowerAlarm.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.17713.8.23.23
snmpwalk -v2c -c public <target> CAMBIUM-PTP800-MIB::rFUTxPowerDegradedAlarm

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.17713.8.23.23.1
snmpget -v2c -c public <target> CAMBIUM-PTP800-MIB::rFUTxPowerDegradedAlarm.1

Start monitoring Cambium Networks PTP 800 licensed microwave wireless bridge with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CAMBIUM-PTP800-MIB::rFUTxPowerDegradedAlarm OID value, configure state conditions and alerts, and monitor any Cambium Networks PTP 800 licensed microwave wireless bridge from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.17713cambiumCAMBIUM-PMP80211-MIB
Numeric OIDNameModule
1.3.6.1.4.1.17713.8ptp800CAMBIUM-PTP800-MIB
1.3.6.1.4.1.17713.8.23rfuCAMBIUM-PTP800-MIB
1.3.6.1.4.1.17713.8.23.23rFUTxPowerDegradedAlarmCAMBIUM-PTP800-MIB