All MIBs › CAMBIUM-PTP800-MIB › rFUCableAlarm
rFUCableAlarm
Module: CAMBIUM-PTP800-MIB
OID (symbolic): CAMBIUM-PTP800-MIB::rFUCableAlarm
OID (numeric): 1.3.6.1.4.1.17713.8.23.21
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: RFU cable detector voltage out of range alarm
What is rFUCableAlarm?
This alarm fires when the RFU's cable detector voltage is out of the expected range ('iFCableVoltageOutOfRange'), typically pointing to a problem with the IF cable connecting the RFU to the indoor unit. It helps admins catch cabling faults that would otherwise degrade the link.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.17713.8.23.21 snmpwalk -v2c -c public <target> CAMBIUM-PTP800-MIB::rFUCableAlarm
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.17713.8.23.21.1 snmpget -v2c -c public <target> CAMBIUM-PTP800-MIB::rFUCableAlarm.1
Start monitoring Cambium Networks PTP 800 licensed microwave wireless bridge with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CAMBIUM-PTP800-MIB::rFUCableAlarm OID value, configure state conditions and alerts, and monitor any Cambium Networks PTP 800 licensed microwave wireless bridge from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.17713 | cambium | CAMBIUM-PMP80211-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.17713.8 | ptp800 | CAMBIUM-PTP800-MIB |
| 1.3.6.1.4.1.17713.8.23 | rfu | CAMBIUM-PTP800-MIB |
| 1.3.6.1.4.1.17713.8.23.21 | rFUCableAlarm | CAMBIUM-PTP800-MIB |