CAMBIUM-PTP800-MIB :: protectionInterfaceStatus

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCAMBIUM-PTP800-MIBprotectionInterfaceStatus

protectionInterfaceStatus

Module: CAMBIUM-PTP800-MIB

OID (symbolic): CAMBIUM-PTP800-MIB::protectionInterfaceStatus

OID (numeric): 1.3.6.1.4.1.17713.8.26.17

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: In a 1+1 Hot Standby configuration, information is shared between neighbor CMUs over the Protection Interface. The Protection Interface Status attribute reports whether the neighbor CMU is successfully responding, physically disconnected or whether it is physically connected but not responding, e.g. powered down.

What is protectionInterfaceStatus?

In a 1+1 Hot Standby configuration, this reports whether the neighbor CMU is responding correctly over the Protection Interface, or whether it's physically disconnected, or physically connected but not responding (e.g. powered down). It's the key health indicator for the link that coordinates the redundant pair.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.17713.8.26.17
snmpwalk -v2c -c public <target> CAMBIUM-PTP800-MIB::protectionInterfaceStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.17713.8.26.17.1
snmpget -v2c -c public <target> CAMBIUM-PTP800-MIB::protectionInterfaceStatus.1

Start monitoring Cambium Networks PTP 800 licensed microwave wireless bridge with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CAMBIUM-PTP800-MIB::protectionInterfaceStatus OID value, configure state conditions and alerts, and monitor any Cambium Networks PTP 800 licensed microwave wireless bridge from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.17713cambiumCAMBIUM-PMP80211-MIB
Numeric OIDNameModule
1.3.6.1.4.1.17713.8ptp800CAMBIUM-PTP800-MIB
1.3.6.1.4.1.17713.8.26protectionStatusCAMBIUM-PTP800-MIB
1.3.6.1.4.1.17713.8.26.17protectionInterfaceStatusCAMBIUM-PTP800-MIB