CAMBIUM-PTP800-MIB :: faultProtectionSwitching

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCAMBIUM-PTP800-MIBfaultProtectionSwitching

faultProtectionSwitching

Module: CAMBIUM-PTP800-MIB

OID (symbolic): CAMBIUM-PTP800-MIB::faultProtectionSwitching

OID (numeric): 1.3.6.1.4.1.17713.8.25.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: In a 1+1 Hot Standby configuration, protection switching on detection of a fault can be enabled/disabled using this attribute.

What is faultProtectionSwitching?

In a 1+1 Hot Standby configuration, this enables or disables automatic protection switching whenever a fault is detected. Disabling it stops the system from switching to the standby unit automatically even if the active unit develops a fault.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.17713.8.25.2
snmpwalk -v2c -c public <target> CAMBIUM-PTP800-MIB::faultProtectionSwitching

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.17713.8.25.2.1
snmpget -v2c -c public <target> CAMBIUM-PTP800-MIB::faultProtectionSwitching.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.17713.8.25.2.1 i <value>

Start monitoring Cambium Networks PTP 800 licensed microwave wireless bridge with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CAMBIUM-PTP800-MIB::faultProtectionSwitching OID value, configure state conditions and alerts, and monitor any Cambium Networks PTP 800 licensed microwave wireless bridge from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.17713cambiumCAMBIUM-PMP80211-MIB
Numeric OIDNameModule
1.3.6.1.4.1.17713.8ptp800CAMBIUM-PTP800-MIB
1.3.6.1.4.1.17713.8.25protectionConfigCAMBIUM-PTP800-MIB