BW-BroadworksApplicationServer :: psOciStatsMaxSystemRequestResponseTime

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBW-BroadworksApplicationServerpsOciStatsMaxSystemRequestResponseTime

psOciStatsMaxSystemRequestResponseTime

Module: BW-BroadworksApplicationServer

OID (symbolic): BW-BroadworksApplicationServer::psOciStatsMaxSystemRequestResponseTime

OID (numeric): 1.3.6.1.4.1.6431.1.6.8.1.13

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-write

Description: Indicates the longest OCI system request response time sampled since the system was started or since this measurement was cleared.

What is psOciStatsMaxSystemRequestResponseTime?

This gauge tracks the slowest response time recorded for a system-level OCI request since the server started or since the value was last reset. It pairs with psOciStatsMinSystemRequestResponseTime to show the full range of observed response times, and can be reset by writing to it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6431.1.6.8.1.13
snmpwalk -v2c -c public <target> BW-BroadworksApplicationServer::psOciStatsMaxSystemRequestResponseTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6431.1.6.8.1.13.1
snmpget -v2c -c public <target> BW-BroadworksApplicationServer::psOciStatsMaxSystemRequestResponseTime.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6431.1.6.8.1.13.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> psOciStatsMaxSystemRequestResponseTime.1

Start monitoring BroadSoft application servers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BW-BroadworksApplicationServer::psOciStatsMaxSystemRequestResponseTime OID value, configure state conditions and alerts, and monitor any BroadSoft application servers from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6431broadsoftBroadworksFault
1.3.6.1.4.1.6431.1broadworksBroadworksFault
Numeric OIDNameModule
1.3.6.1.4.1.6431.1.6provisioningServerBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.6.8psOciModuleBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.6.8.1psOciStatsBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.6.8.1.13psOciStatsMaxSystemRequestResponseTimeBW-BroadworksApplicationServer