BW-BroadworksApplicationServer :: bwTrunkGroupPerTGUnreachableDestinationExceededOffsetValue

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBW-BroadworksApplicationServerbwTrunkGroupPerTGUnreachableDestinationExceededOffsetValue

bwTrunkGroupPerTGUnreachableDestinationExceededOffsetValue

Module: BW-BroadworksApplicationServer

OID (symbolic): BW-BroadworksApplicationServer::bwTrunkGroupPerTGUnreachableDestinationExceededOffsetValue

OID (numeric): 1.3.6.1.4.1.6431.1.2.11.63.7.1.11

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Indicates the value of the Unreachable Destination Exceeded Offset Value parameter for a trunk group.

What is bwTrunkGroupPerTGUnreachableDestinationExceededOffsetValue?

Reports the offset value used after an Unreachable Destination Exceeded alarm has already fired on this trunk group, so the alarm doesn't re-trigger until the unreachable count drops this much further below the initial threshold.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6431.1.2.11.63.7.1.11
snmpwalk -v2c -c public <target> BW-BroadworksApplicationServer::bwTrunkGroupPerTGUnreachableDestinationExceededOffsetValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6431.1.2.11.63.7.1.11.1
snmpget -v2c -c public <target> BW-BroadworksApplicationServer::bwTrunkGroupPerTGUnreachableDestinationExceededOffsetValue.1

Start monitoring BroadSoft application servers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BW-BroadworksApplicationServer::bwTrunkGroupPerTGUnreachableDestinationExceededOffsetValue OID value, configure state conditions and alerts, and monitor any BroadSoft application servers from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6431broadsoftBroadworksFault
1.3.6.1.4.1.6431.1broadworksBroadworksFault
Numeric OIDNameModule
1.3.6.1.4.1.6431.1.2executionServerBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.2.11servicesBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.2.11.63trunkGroupBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.2.11.63.7bwTrunkGroupPerTGTableBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.2.11.63.7.1bwTrunkGroupPerTGEntryBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.2.11.63.7.1.11bwTrunkGroupPerTGUnreachableDestinationExceededOffsetValueBW-BroadworksApplicationServer