All MIBs › BW-BroadworksApplicationServer › bwMGCPStatsSetupSignalDelay
bwMGCPStatsSetupSignalDelay
Module: BW-BroadworksApplicationServer
OID (symbolic): BW-BroadworksApplicationServer::bwMGCPStatsSetupSignalDelay
OID (numeric): 1.3.6.1.4.1.6431.1.2.1.1.31
Node type: OBJECT-TYPE
Type: Gauge32
Access: read-write
Description: This gauge is applicable to MGCP originated calls. It measures the average time (in milliseconds) it takes between the receipt of a NTFY message with digits dialed for the origination of a new call and the transmission of an INVITE (Sip terminator), RQNT (MGCP terminator with in-band ringback), or CRCX (MGCP terminator without in-band ringback) to the primary device of the original called party (in the case of intra-group call) or to the network element of the original called party (in the case of a call to the PSTN). Delays incurred by a dip to the Network Server are removed from the measurement. This measurement is intended to reflect internal queuing, scheduling, and processing delays. The same clarifications as for bwSipStatsSetupSignalDelay apply to bwMGCPStatsSetupSignalDelay
What is bwMGCPStatsSetupSignalDelay?
Measures the average internal delay, in milliseconds, between the Application Server receiving dialed digits for an MGCP-originated call and sending the outbound signaling message (INVITE, RQNT, or CRCX) toward the called party or the PSTN. It isolates the server's own queuing and processing time by excluding any delay caused by a lookup to the Network Server.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6431.1.2.1.1.31 snmpwalk -v2c -c public <target> BW-BroadworksApplicationServer::bwMGCPStatsSetupSignalDelay
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6431.1.2.1.1.31.1 snmpget -v2c -c public <target> BW-BroadworksApplicationServer::bwMGCPStatsSetupSignalDelay.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.6431.1.2.1.1.31.1 i <value>
Start monitoring BroadSoft application servers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BW-BroadworksApplicationServer::bwMGCPStatsSetupSignalDelay OID value, configure state conditions and alerts, and monitor any BroadSoft application servers from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6431 | broadsoft | BroadworksFault |
| 1.3.6.1.4.1.6431.1 | broadworks | BroadworksFault |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6431.1.2 | executionServer | BW-BroadworksApplicationServer |
| 1.3.6.1.4.1.6431.1.2.1 | mgcpModule | BW-BroadworksApplicationServer |
| 1.3.6.1.4.1.6431.1.2.1.1 | mgcpStats | BW-BroadworksApplicationServer |
| 1.3.6.1.4.1.6431.1.2.1.1.31 | bwMGCPStatsSetupSignalDelay | BW-BroadworksApplicationServer |