BW-BroadworksApplicationServer :: bwMGCPStatsMGCPCommandOuts

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBW-BroadworksApplicationServerbwMGCPStatsMGCPCommandOuts

bwMGCPStatsMGCPCommandOuts

Module: BW-BroadworksApplicationServer

OID (symbolic): BW-BroadworksApplicationServer::bwMGCPStatsMGCPCommandOuts

OID (numeric): 1.3.6.1.4.1.6431.1.2.1.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-write

Description: This counter reflects the number of MGCP commands sent out by BroadWorks

What is bwMGCPStatsMGCPCommandOuts?

Counts the total number of MGCP commands the Application Server has sent out.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6431.1.2.1.1.1
snmpwalk -v2c -c public <target> BW-BroadworksApplicationServer::bwMGCPStatsMGCPCommandOuts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6431.1.2.1.1.1.1
snmpget -v2c -c public <target> BW-BroadworksApplicationServer::bwMGCPStatsMGCPCommandOuts.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6431.1.2.1.1.1.1 i <value>

Start monitoring BroadSoft application servers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BW-BroadworksApplicationServer::bwMGCPStatsMGCPCommandOuts OID value, configure state conditions and alerts, and monitor any BroadSoft application servers from a single console.

How to Use in IPNetwork Monitor

Select a BroadSoft application server as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type bwMGCPStatsMGCPCommandOuts into the Find box to locate it in the OID tree, then select it and click OK. This counter reflects the number of MGCP commands sent out by BroadWorks. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6431broadsoftBroadworksFault
1.3.6.1.4.1.6431.1broadworksBroadworksFault
Numeric OIDNameModule
1.3.6.1.4.1.6431.1.2executionServerBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.2.1mgcpModuleBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.2.1.1mgcpStatsBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.2.1.1.1bwMGCPStatsMGCPCommandOutsBW-BroadworksApplicationServer