BW-BroadworksApplicationServer :: bwMGCPStatsEndpointConfigurationResponseIns

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBW-BroadworksApplicationServerbwMGCPStatsEndpointConfigurationResponseIns

bwMGCPStatsEndpointConfigurationResponseIns

Module: BW-BroadworksApplicationServer

OID (symbolic): BW-BroadworksApplicationServer::bwMGCPStatsEndpointConfigurationResponseIns

OID (numeric): 1.3.6.1.4.1.6431.1.2.1.1.22.1.2

Node type: OBJECT-TYPE

Type: Counter32

Access: read-write

Description: This counter represents the number of MGCP responses received by BroadWorks in response to an Endpoint Configuration command sent.

What is bwMGCPStatsEndpointConfigurationResponseIns?

Counts the MGCP responses the Application Server received after sending an Endpoint Configuration command (bwMGCPStatsEndpointConfigurationOuts).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6431.1.2.1.1.22.1.2
snmpwalk -v2c -c public <target> BW-BroadworksApplicationServer::bwMGCPStatsEndpointConfigurationResponseIns

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6431.1.2.1.1.22.1.2.1
snmpget -v2c -c public <target> BW-BroadworksApplicationServer::bwMGCPStatsEndpointConfigurationResponseIns.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6431.1.2.1.1.22.1.2.1 i <value>

Start monitoring BroadSoft application servers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BW-BroadworksApplicationServer::bwMGCPStatsEndpointConfigurationResponseIns OID value, configure state conditions and alerts, and monitor any BroadSoft application servers from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6431broadsoftBroadworksFault
1.3.6.1.4.1.6431.1broadworksBroadworksFault
Numeric OIDNameModule
1.3.6.1.4.1.6431.1.2executionServerBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.2.1mgcpModuleBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.2.1.1mgcpStatsBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.2.1.1.22bwMGCPStatsEndpointConfigurationResponseTableBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.2.1.1.22.1bwMGCPStatsEndpointConfigurationResponseEntryBW-BroadworksApplicationServer
1.3.6.1.4.1.6431.1.2.1.1.22.1.2bwMGCPStatsEndpointConfigurationResponseInsBW-BroadworksApplicationServer