BROCADE-MODULE-MEM-UTIL-MIB :: bcsiModuleMemAvailable

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › BROCADE-MODULE-MEM-UTIL-MIB › bcsiModuleMemAvailable

bcsiModuleMemAvailable

Module: BROCADE-MODULE-MEM-UTIL-MIB

OID (symbolic): BROCADE-MODULE-MEM-UTIL-MIB::bcsiModuleMemAvailable

OID (numeric): 1.3.6.1.4.1.1588.3.1.13.1.1.1.3

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: The available total memory in kilobytes within this module.

What is bcsiModuleMemAvailable?

Reports the amount of free memory (in kilobytes) currently available on a specific module. Track this value to detect memory pressure that could affect module stability or performance.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1588.3.1.13.1.1.1.3
snmpwalk -v2c -c public <target> BROCADE-MODULE-MEM-UTIL-MIB::bcsiModuleMemAvailable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1588.3.1.13.1.1.1.3.1
snmpget -v2c -c public <target> BROCADE-MODULE-MEM-UTIL-MIB::bcsiModuleMemAvailable.1

Start monitoring Brocade modular chassis switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BROCADE-MODULE-MEM-UTIL-MIB::bcsiModuleMemAvailable OID value, configure state conditions and alerts, and monitor any Brocade modular chassis switches from a single console.

How to Use in IPNetwork Monitor

Select a Brocade modular chassis switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type bcsiModuleMemAvailable into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The available total memory in kilobytes within this module. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the value drifts significantly from its normal baseline (in kilo Bytes), since an unexpected change often points to a real underlying issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1588bcsiBrocade-REG-MIB
1.3.6.1.4.1.1588.3bcsiRegBrocade-REG-MIB
1.3.6.1.4.1.1588.3.1bcsiModulesBrocade-REG-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1588.3.1.13brocadeModuleMemUtilMIBBROCADE-MODULE-MEM-UTIL-MIB
1.3.6.1.4.1.1588.3.1.13.1bcsiModuleMemUtilObjectsBROCADE-MODULE-MEM-UTIL-MIB
1.3.6.1.4.1.1588.3.1.13.1.1bcsiModuleMemUtilTableBROCADE-MODULE-MEM-UTIL-MIB
1.3.6.1.4.1.1588.3.1.13.1.1.1bcsiModuleMemUtilEntryBROCADE-MODULE-MEM-UTIL-MIB
1.3.6.1.4.1.1588.3.1.13.1.1.1.3bcsiModuleMemAvailableBROCADE-MODULE-MEM-UTIL-MIB