All MIBs › BROADCOM-POWER-ETHERNET-MIB › agentPethPowerDetectionType
agentPethPowerDetectionType
Module: BROADCOM-POWER-ETHERNET-MIB
OID (symbolic): BROADCOM-POWER-ETHERNET-MIB::agentPethPowerDetectionType
OID (numeric): 1.3.6.1.4.1.4526.10.15.1.1.1.8
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Describes PD detection mechanism performed by the PSE port. A value of none(0) means no detection is done. A value of legacy(1) means only legacy capacitive detection scheme is used. A value of 4ptdot3afonly(2) means that IEEE 802.3af 4point detection scheme is used. A value of 4ptdot3afandlegacy(3)means that IEEE 802.3af 4point detection scheme is used and when that fails to detect a connected PD, legacity capacitive detection is used. A value of 2ptdot3afonly(4) means that IEEE 802.3af 2point detection scheme is used. A value of 2ptdot3afandlegacy(5)means that IEEE 802.3af 2point detection scheme is used and when that fails to detect a connected PD, legacity capacitive detection is used. The value 'none' can not be forcibly set by the administrator.
What is agentPethPowerDetectionType?
Selects the detection scheme this PSE port uses to identify a connected powered device, ranging from no detection(0), legacy capacitive-only detection(1), various 4-point or 2-point IEEE 802.3af detection modes, and combined 802.3af-plus-legacy fallback modes; the none(0) value cannot be forced by an admin, it only appears if detection genuinely fails.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4526.10.15.1.1.1.8 snmpwalk -v2c -c public <target> BROADCOM-POWER-ETHERNET-MIB::agentPethPowerDetectionType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4526.10.15.1.1.1.8.1 snmpget -v2c -c public <target> BROADCOM-POWER-ETHERNET-MIB::agentPethPowerDetectionType.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.4526.10.15.1.1.1.8.1 i <value>
Start monitoring Netgear PoE switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BROADCOM-POWER-ETHERNET-MIB::agentPethPowerDetectionType OID value, configure state conditions and alerts, and monitor any Netgear PoE switches from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4526 | netgear | FSM726S-MIB |
| 1.3.6.1.4.1.4526.10 | ng7000managedswitch | Netgear-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4526.10.15 | fastPathpowerEthernetMIB | BROADCOM-POWER-ETHERNET-MIB |
| 1.3.6.1.4.1.4526.10.15.1 | agentPethObjects | BROADCOM-POWER-ETHERNET-MIB |
| 1.3.6.1.4.1.4526.10.15.1.1 | agentPethPsePortTable | BROADCOM-POWER-ETHERNET-MIB |
| 1.3.6.1.4.1.4526.10.15.1.1.1 | agentPethPsePortEntry | BROADCOM-POWER-ETHERNET-MIB |
| 1.3.6.1.4.1.4526.10.15.1.1.1.8 | agentPethPowerDetectionType | BROADCOM-POWER-ETHERNET-MIB |