battChargerState

Module: BRCM-BATTERY-MGMT-MIB

OID (symbolic): BRCM-BATTERY-MGMT-MIB::battChargerState

OID (numeric): 1.3.6.1.4.1.4413.50.1.1.2.1.10.2.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The current state of the battery charger. Note that all states may not be supported on all types of chargers.

What is battChargerState?

Reports the current operational state of the battery charger, such as charging, discharging, idle, or fault. Monitoring this value provides real-time visibility into the charger's activity and health.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4413.50.1.1.2.1.10.2.4
snmpwalk -v2c -c public <target> BRCM-BATTERY-MGMT-MIB::battChargerState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4413.50.1.1.2.1.10.2.4.1
snmpget -v2c -c public <target> BRCM-BATTERY-MGMT-MIB::battChargerState.1

Start monitoring Broadcom-chipset DOCSIS cable modems/gateways with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BRCM-BATTERY-MGMT-MIB::battChargerState OID value, configure state conditions and alerts, and monitor any Broadcom-chipset DOCSIS cable modems/gateways from a single console.

How to Use in IPNetwork Monitor

Select a Broadcom-chipset DOCSIS cable modems/gateway as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type battChargerState into the Find box to locate it in the OID tree, then select it and click OK. The current state of the battery charger. Note that all states may not be supported on all types of chargers. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is 'forcedDischarge' or 'eternalSleep', since those indicate the battery charger has stopped normal charge cycling due to a fault. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4413broadcomBASP-Config-MIB
1.3.6.1.4.1.4413.50brcmCableDataBRCM-CABLEDATA-SMI
1.3.6.1.4.1.4413.50.1cableDataBRCM-CABLEDATA-SMI
1.3.6.1.4.1.4413.50.1.1cableDataMgmtBRCM-CABLEDATA-SMI
1.3.6.1.4.1.4413.50.1.1.2cableDataMgmtMIBBRCM-CABLEDATA-MGMT-MIB
1.3.6.1.4.1.4413.50.1.1.2.1cableDataMgmtMIBObjectsBRCM-CABLEDATA-MGMT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4413.50.1.1.2.1.10batteryMgmtBRCM-BATTERY-MGMT-MIB
1.3.6.1.4.1.4413.50.1.1.2.1.10.2batteryChargerBRCM-BATTERY-MGMT-MIB
1.3.6.1.4.1.4413.50.1.1.2.1.10.2.4battChargerStateBRCM-BATTERY-MGMT-MIB