BRCD-DOT1X-MIB :: brcdDot1xAuthPortStatRxEAPFrames

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBRCD-DOT1X-MIBbrcdDot1xAuthPortStatRxEAPFrames

brcdDot1xAuthPortStatRxEAPFrames

Module: BRCD-DOT1X-MIB

OID (symbolic): BRCD-DOT1X-MIB::brcdDot1xAuthPortStatRxEAPFrames

OID (numeric): 1.3.6.1.4.1.1991.1.1.3.38.2.1.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The total number of EAPOL frames received on the port It includes EAP frames -

What is brcdDot1xAuthPortStatRxEAPFrames?

Reports the cumulative total of all EAPOL frames received on a specific port, including all types of EAP frames. This counter helps monitor the overall volume of 802.1x authentication traffic arriving at the port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1991.1.1.3.38.2.1.1.1
snmpwalk -v2c -c public <target> BRCD-DOT1X-MIB::brcdDot1xAuthPortStatRxEAPFrames

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1991.1.1.3.38.2.1.1.1.1
snmpget -v2c -c public <target> BRCD-DOT1X-MIB::brcdDot1xAuthPortStatRxEAPFrames.1

Start monitoring Brocade Communications managed switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BRCD-DOT1X-MIB::brcdDot1xAuthPortStatRxEAPFrames OID value, configure state conditions and alerts, and monitor any Brocade Communications managed switches from a single console.

How to Use in IPNetwork Monitor

Select a Brocade Communications managed switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type brcdDot1xAuthPortStatRxEAPFrames into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total number of EAPOL frames received on the port It includes EAP frames -. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1991foundryFOUNDRY-SN-ROOT-MIB
1.3.6.1.4.1.1991.1productsFOUNDRY-SN-ROOT-MIB
1.3.6.1.4.1.1991.1.1switchFOUNDRY-SN-ROOT-MIB
1.3.6.1.4.1.1991.1.1.3snSwitchFOUNDRY-SN-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1991.1.1.3.38brcdDot1xAuthBRCD-DOT1X-MIB
1.3.6.1.4.1.1991.1.1.3.38.2brcdDot1xAuthPortStatisticsBRCD-DOT1X-MIB
1.3.6.1.4.1.1991.1.1.3.38.2.1brcdDot1xAuthPortStatTableBRCD-DOT1X-MIB
1.3.6.1.4.1.1991.1.1.3.38.2.1.1brcdDot1xAuthPortStatEntryBRCD-DOT1X-MIB
1.3.6.1.4.1.1991.1.1.3.38.2.1.1.1brcdDot1xAuthPortStatRxEAPFramesBRCD-DOT1X-MIB