BETASITE-MIB :: usrChassisActiveCalls

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › BETASITE-MIB › usrChassisActiveCalls

usrChassisActiveCalls

Module: BETASITE-MIB

OID (symbolic): BETASITE-MIB::usrChassisActiveCalls

OID (numeric): 1.3.6.1.4.1.429.4.76.1.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The number of active calls on the chassis at that moment.

What is usrChassisActiveCalls?

This Integer32 counts the number of active call sessions on the chassis at the moment of querying, reflecting real-time call capacity usage. Example: an activeCalls value of 45 means 45 calls are in progress out of the maximum available.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.429.4.76.1.1
snmpwalk -v2c -c public <target> BETASITE-MIB::usrChassisActiveCalls

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.429.4.76.1.1.1
snmpget -v2c -c public <target> BETASITE-MIB::usrChassisActiveCalls.1

Start monitoring 3Com CommWorks broadband/VoIP access equipment (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BETASITE-MIB::usrChassisActiveCalls OID value, configure state conditions and alerts, and monitor any 3Com CommWorks broadband/VoIP access equipment (legacy) from a single console.

How to Use in IPNetwork Monitor

Select a 3Com CommWorks broadband/VoIP access equipment (legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type usrChassisActiveCalls into the Find box to locate it in the OID tree, then select it and click OK. The number of active calls on the chassis at that moment. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the count changes from its expected baseline, since that would indicate the underlying set of items changed unexpectedly. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.429usrANIC-MIB
1.3.6.1.4.1.429.4commonHDR2-MIB
Numeric OIDNameModule
1.3.6.1.4.1.429.4.76usrBetaSiteBETASITE-MIB
1.3.6.1.4.1.429.4.76.1usrBetaObjsBETASITE-MIB
1.3.6.1.4.1.429.4.76.1.1usrChassisActiveCallsBETASITE-MIB