All MIBs › BAS-ALIAS-CABLE-DEVICE-MIB › basDocsDevEvThrottleThreshold
basDocsDevEvThrottleThreshold
Module: BAS-ALIAS-CABLE-DEVICE-MIB
OID (symbolic): BAS-ALIAS-CABLE-DEVICE-MIB::basDocsDevEvThrottleThreshold
OID (numeric): 1.3.6.1.4.1.3493.2.7.9.1.1.5.1.1.5
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-write
Description: Number of trap/syslog events per docsDevEvThrottleInterval to be transmitted before throttling.
A single event is always treated as a single event for threshold counting. That is, an event causing both a trap and a syslog message is still treated as a single event.
What is basDocsDevEvThrottleThreshold?
Specifies the maximum number of trap or syslog events the cable device may transmit within the configured throttle interval before throttling kicks in. This setting prevents event floods from consuming excessive network or management resources.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3493.2.7.9.1.1.5.1.1.5 snmpwalk -v2c -c public <target> BAS-ALIAS-CABLE-DEVICE-MIB::basDocsDevEvThrottleThreshold
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3493.2.7.9.1.1.5.1.1.5.1 snmpget -v2c -c public <target> BAS-ALIAS-CABLE-DEVICE-MIB::basDocsDevEvThrottleThreshold.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.3493.2.7.9.1.1.5.1.1.5.1 i <value>
Start monitoring Broadband Access Systems (BAS) CMTS (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BAS-ALIAS-CABLE-DEVICE-MIB::basDocsDevEvThrottleThreshold OID value, configure state conditions and alerts, and monitor any Broadband Access Systems (BAS) CMTS (legacy) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.3493 | basMIB | BAS-MIB |
| 1.3.6.1.4.1.3493.2 | basMibGroup | BAS-MIB |
| 1.3.6.1.4.1.3493.2.7 | basAlias | BAS-MIB |
| 1.3.6.1.4.1.3493.2.7.9 | basAliasDocsCd | BAS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3493.2.7.9.1 | basAliasDocsCdMib | BAS-ALIAS-CABLE-DEVICE-MIB |
| 1.3.6.1.4.1.3493.2.7.9.1.1 | basDocsDevMIBObjects | BAS-ALIAS-CABLE-DEVICE-MIB |
| 1.3.6.1.4.1.3493.2.7.9.1.1.5 | basDocsDevEvent | BAS-ALIAS-CABLE-DEVICE-MIB |
| 1.3.6.1.4.1.3493.2.7.9.1.1.5.1 | basDocsDevEvTable | BAS-ALIAS-CABLE-DEVICE-MIB |
| 1.3.6.1.4.1.3493.2.7.9.1.1.5.1.1 | basDocsDevEvEntry | BAS-ALIAS-CABLE-DEVICE-MIB |
| 1.3.6.1.4.1.3493.2.7.9.1.1.5.1.1.5 | basDocsDevEvThrottleThreshold | BAS-ALIAS-CABLE-DEVICE-MIB |