AtiStackInfo-MIB :: atiswitchEnhStackRemoteNumber

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › AtiStackInfo-MIB › atiswitchEnhStackRemoteNumber

atiswitchEnhStackRemoteNumber

Module: AtiStackInfo-MIB

OID (symbolic): AtiStackInfo-MIB::atiswitchEnhStackRemoteNumber

OID (numeric): 1.3.6.1.4.1.207.8.16.1.3

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Total number of remote switches detected by the Master. It will also be equal to the number of entries in atiswitchEnhStackTable.

What is atiswitchEnhStackRemoteNumber?

Reports the total number of remote switches that the Master switch has detected in the enhanced stack. This value also corresponds to the number of entries in the enhanced stack table.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.207.8.16.1.3
snmpwalk -v2c -c public <target> AtiStackInfo-MIB::atiswitchEnhStackRemoteNumber

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.207.8.16.1.3.1
snmpget -v2c -c public <target> AtiStackInfo-MIB::atiswitchEnhStackRemoteNumber.1

Start monitoring Allied Telesyn (Allied Telesis) stackable Layer 2 switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AtiStackInfo-MIB::atiswitchEnhStackRemoteNumber OID value, configure state conditions and alerts, and monitor any Allied Telesyn (Allied Telesis) stackable Layer 2 switches (legacy) from a single console.

How to Use in IPNetwork Monitor

Select an Allied Telesyn (Allied Telesis) stackable Layer 2 switch (legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type atiswitchEnhStackRemoteNumber into the Find box to locate it in the OID tree, then select it and click OK. It reports the total number of remote switches detected by the Master. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the count changes from its expected baseline, since that would indicate the underlying set of items changed unexpectedly. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.207alliedTelesynAT-RG600-MIB
1.3.6.1.4.1.207.8mibObjectAT-RG600-MIB
Numeric OIDNameModule
1.3.6.1.4.1.207.8.16atiStackInfoMibAtiStackInfo-MIB
1.3.6.1.4.1.207.8.16.1atiswitchEnhancedStackingAtiStackInfo-MIB
1.3.6.1.4.1.207.8.16.1.3atiswitchEnhStackRemoteNumberAtiStackInfo-MIB