ASKEY-ENTITY-ALARM-MIB :: aeHistoryAlarmTableSize

MIB Reference — IPNetwork Monitor

All MIBsASKEY-ENTITY-ALARM-MIBaeHistoryAlarmTableSize

aeHistoryAlarmTableSize

Module: ASKEY-ENTITY-ALARM-MIB

OID (symbolic): ASKEY-ENTITY-ALARM-MIB::aeHistoryAlarmTableSize

OID (numeric): 1.3.6.1.4.1.3646.1300.2.12.1.4.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description:

The size of the aeHistoryAlarmTable in rows. A value of 0 means no alarm logged in this table.

What is aeHistoryAlarmTableSize?

This read-only OID reports the number of rows currently stored in the historical alarm table. A value of zero indicates no alarms have been logged to the history table.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3646.1300.2.12.1.4.1
snmpwalk -v2c -c public <target> ASKEY-ENTITY-ALARM-MIB::aeHistoryAlarmTableSize

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3646.1300.2.12.1.4.1.1
snmpget -v2c -c public <target> ASKEY-ENTITY-ALARM-MIB::aeHistoryAlarmTableSize.1

How to Use in IPNetwork Monitor

Select an Askey RTV7906VW as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and locate aeHistoryAlarmTableSize under the aeAlarmHistory branch of ASKEY-ENTITY-ALARM-MIB, then select it and click OK. It reports how many rows are currently present in the device's alarm history table — 0 means no alarm has ever been logged. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value rises above 0 (or above a small baseline count), so a new alarm being logged doesn't go unnoticed. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.3646askeyASKEY-DSLAM-MIB
1.3.6.1.4.1.3646.1300asd300ASKEY-DSLAM-MIB
1.3.6.1.4.1.3646.1300.2ipDslamASKEY-DSLAM-MIB
1.3.6.1.4.1.3646.1300.2.12askeyEntityAlarmMIBASKEY-ENTITY-ALARM-MIB
1.3.6.1.4.1.3646.1300.2.12.1askeyEntityAlarmMIBObjectsASKEY-ENTITY-ALARM-MIB
1.3.6.1.4.1.3646.1300.2.12.1.4aeAlarmHistoryASKEY-ENTITY-ALARM-MIB
1.3.6.1.4.1.3646.1300.2.12.1.4.1aeHistoryAlarmTableSizeASKEY-ENTITY-ALARM-MIB