APS-MIB :: apsStatusModeMismatches

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › APS-MIB › apsStatusModeMismatches

apsStatusModeMismatches

Module: APS-MIB

OID (symbolic): APS-MIB::apsStatusModeMismatches

OID (numeric): 1.3.6.1.2.1.10.49.1.2.1.4

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: A count of Mode Mismatch conditions.

Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of apsStatusDiscontinuityTime.

What is apsStatusModeMismatches?

Counts the number of times a Mode Mismatch condition has been detected, which occurs when the APS architecture or directionality indicated in the K2 byte conflicts between the local and remote ends of the protection channel.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.49.1.2.1.4
snmpwalk -v2c -c public <target> APS-MIB::apsStatusModeMismatches

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.10.49.1.2.1.4.1
snmpget -v2c -c public <target> APS-MIB::apsStatusModeMismatches.1

Start monitoring SONET/SDH optical transport equipment (linear APS) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the APS-MIB::apsStatusModeMismatches OID value, configure state conditions and alerts, and monitor any SONET/SDH optical transport equipment (linear APS) from a single console.

How to Use in IPNetwork Monitor

Select an SONET/SDH optical transport equipment (linear APS) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type apsStatusModeMismatches into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports a count of Mode Mismatch conditions. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of apsStatusDiscontinuityTime. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAPERTUS-NPG-MIB
1.3.6.1.2.1mib_2AXON-MIB
1.3.6.1.2.1.10transmissionCHECKPOINT-MIB-2
Numeric OIDNameModule
1.3.6.1.2.1.10.49apsMIBAPS-MIB
1.3.6.1.2.1.10.49.1apsMIBObjectsAPS-MIB
1.3.6.1.2.1.10.49.1.2apsStatusTableAPS-MIB
1.3.6.1.2.1.10.49.1.2.1apsStatusEntryAPS-MIB
1.3.6.1.2.1.10.49.1.2.1.4apsStatusModeMismatchesAPS-MIB