APS-MIB-JUNI :: junidApsConfigSdBerThreshold

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › APS-MIB-JUNI › junidApsConfigSdBerThreshold

junidApsConfigSdBerThreshold

Module: APS-MIB-JUNI

OID (symbolic): APS-MIB-JUNI::junidApsConfigSdBerThreshold

OID (numeric): 1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.7

Node type: OBJECT-TYPE

Type: Integer32

Access: read-create

Description: The Signal Degrade Bit Error Rate.

The negated value of this number is used as the exponent of 10 for computing the threshold value for the Bit Error Rate (BER). For example, a value of 5 indicates a BER threshold of 10^-5.

This object may be modified if the associated junidApsConfigRowStatus object is equal to active(1).

What is junidApsConfigSdBerThreshold?

This read-create integer (5-9) sets Signal Degrade BER threshold as 10^-N. Network engineers configure this for signal quality monitoring. A value of 5 means 10^-5 BER threshold.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4874juniperUniJuniper-UNI-SMI
1.3.6.1.4.1.4874.3juniperUniExperimentJuniper-UNI-SMI
1.3.6.1.4.1.4874.3.2juniExperimentJuniper-Experiment
1.3.6.1.4.1.4874.3.2.2juniSonetApsExperimentJuniper-Experiment
Numeric OIDNameModule
1.3.6.1.4.1.4874.3.2.2.1junidApsMIBAPS-MIB-JUNI
1.3.6.1.4.1.4874.3.2.2.1.1junidApsMIBObjectsAPS-MIB-JUNI
1.3.6.1.4.1.4874.3.2.2.1.1.1junidApsConfigAPS-MIB-JUNI
1.3.6.1.4.1.4874.3.2.2.1.1.1.2junidApsConfigTableAPS-MIB-JUNI
1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1junidApsConfigEntryAPS-MIB-JUNI
1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.7junidApsConfigSdBerThresholdAPS-MIB-JUNI