APEX9-MIB :: cnfFceRadOptLat

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAPEX9-MIBcnfFceRadOptLat

cnfFceRadOptLat

Module: APEX9-MIB

OID (symbolic): APEX9-MIB::cnfFceRadOptLat

OID (numeric): 1.3.6.1.4.1.39229.1.1.2.2.3.3.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Low latency mode disabled/enabled

What is cnfFceRadOptLat?

This read-write OID enables or disables low-latency mode on the FCE radio link. Enabling this mode reduces end-to-end transmission delay, which is important for latency-sensitive applications such as voice or real-time control traffic.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.39229.1.1.2.2.3.3.8
snmpwalk -v2c -c public <target> APEX9-MIB::cnfFceRadOptLat

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.39229.1.1.2.2.3.3.8.1
snmpget -v2c -c public <target> APEX9-MIB::cnfFceRadOptLat.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.39229.1.1.2.2.3.3.8.1 i <value>

Start monitoring BigBand Networks APEX9 (LL-1000) video gateway (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the APEX9-MIB::cnfFceRadOptLat OID value, configure state conditions and alerts, and monitor any BigBand Networks APEX9 (LL-1000) video gateway (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.39229apex9APEX9-MIB
1.3.6.1.4.1.39229.1brandAPEX9-MIB
1.3.6.1.4.1.39229.1.1productsAPEX9-MIB
1.3.6.1.4.1.39229.1.1.2ll1000APEX9-MIB
1.3.6.1.4.1.39229.1.1.2.2cnfFceAPEX9-MIB
1.3.6.1.4.1.39229.1.1.2.2.3cnfFceRadAPEX9-MIB
1.3.6.1.4.1.39229.1.1.2.2.3.3cnfFceRadOptAPEX9-MIB
1.3.6.1.4.1.39229.1.1.2.2.3.3.8cnfFceRadOptLatAPEX9-MIB